Paper
26 January 2016 The effective area calibration precision analysis of grazing incidence soft x-ray optical system
Yongqiang Shi, Zhiwu Mei, Zhengxin Lv, Loulou Deng
Author Affiliations +
Proceedings Volume 9796, Selected Papers of the Photoelectronic Technology Committee Conferences held November 2015; 97961P (2016) https://doi.org/10.1117/12.2228885
Event: Selected Proceedings of the Chinese Society for Optical Engineering Conferences held November 2015, 2015, Various, China
Abstract
The grazing incidence soft X-ray optical system is the core equipment of future space science missions. The optical system expands the collecting area of x-ray photos and improves the SNR. The effective area calibration is the key indicator for testing and verifying the performance of the grazing incidence optical system. One of the traditional calibration methods uses the wide x-ray beam as the calibration x-ray source. This calibration method requires large ground equipment, high environmental conditions while the x-ray beam is not so parallel that the calibration accuracy is limited. Another effective area calibration method uses the narrow x-ray beam scan the optical system. In this paper, the above two effective area calibration methods of the grazing incidence optical system are modeled mathematically. The factors such as the parallelism of the beam, the uniformity of the beam and the characteristics of optical system are absorbed into the unified mathematical model for describing the effective area. The key factors which affect the effective area calibration accuracy are extracted, and their influences on the calibration result are analyzed. Eventually the two calibration methods accuracy is evaluated and the ways for improving the calibration accuracy are given. The effective area calibration is able to test and verify the collecting ability of x-ray photons of the grazing incidence optical system, which is the basis for the development of soft x-ray optics.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yongqiang Shi, Zhiwu Mei, Zhengxin Lv, and Loulou Deng "The effective area calibration precision analysis of grazing incidence soft x-ray optical system", Proc. SPIE 9796, Selected Papers of the Photoelectronic Technology Committee Conferences held November 2015, 97961P (26 January 2016); https://doi.org/10.1117/12.2228885
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

X-rays

Grazing incidence

Sensors

X-ray optics

X-ray sources

Reflectivity

RELATED CONTENT


Back to Top