Additionally the mirror blanks need to be dimensionally stable for more than 30 years. In particular, stress effects due to the changes in the environment shall not entail shape variation of more than 0.5 μm PV within 30 years. In 2010 SCHOTT developed a physically based model to describe the thermal and mechanical long time behavior of ZERODUR. The model enables simulation of the long time behavior of ZERODUR mirror blanks under realistic mechanical and thermal constraints. This presentation shows FEM simulation results on the long time behavior of the ELT M1, M2 and M3 mirror blanks under different loading conditions. Additionally the model results will be compared to an already 15 years lasting long time measurement of a ZERODUR sample at the German federal physical standardization institute (PTB). In recent years SCHOTT pushed the push rod dilatometer measurement technology to its limit. With the new Advanced Dilatometer CTE measurement accuracies of +- 3 ppb/K and reproducibilities of better 1 ppb/K have been achieved. The new Advanced Dilatometer exhibits excellent long time stability. |
ACCESS THE FULL ARTICLE
No SPIE Account? Create one
CITATIONS
Cited by 1 scholarly publication.
Mirrors
Mirrors
Temperature metrology
Thermal modeling
Zerodur
Zerodur
Finite element methods