Paper
27 July 2016 New progress in electron-injection detectors for NIR imagers with low noise and high frame rates
Author Affiliations +
Abstract
This article reports the progress on the development of a novel detector with the promise of addressing the needs of extreme AO (ExAO) in the near-IR band (NIR), 0.9-1.7 μm. The camera is based on the electron injection mechanism which resembles how the human eye processes light. The camera design allows high sensitivity operation at TEC reachable temperatures for ExAO at 1-4 kHz frame rates, and at the same time the concept produces sufficient gain to overcome the read noise of the device. Here we present the overall design, test results on Gen-1 (outdated but operable) camera, along with early results of our next generation of detectors.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Mohsen Rezaei, Min-Su Park, Skylar Wheaton, Chee Leong Tan, Vala Fathipour, Olivier Guyon, Melville P. Ulmer, and Hooman Mohseni "New progress in electron-injection detectors for NIR imagers with low noise and high frame rates", Proc. SPIE 9915, High Energy, Optical, and Infrared Detectors for Astronomy VII, 99150P (27 July 2016); https://doi.org/10.1117/12.2233657
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications and 1 patent.