Paper
19 October 2016 Resolution allocation and budget of the Lyman-α ultraviolet telescope
Author Affiliations +
Proceedings Volume 10154, Advanced Optical Design and Manufacturing Technology and Astronomical Telescopes and Instrumentation; 101541C (2016) https://doi.org/10.1117/12.2246786
Event: International Symposium on Optoelectronic Technology and Application 2016, 2016, Beijing, China
Abstract
As a high-resolution imaging instrument, angular resolution is the most important index of Lyman-α ultraviolet telescope. In this paper a new allocation and budget method is introduced. An resolution error allocation of surface roughness, figure error and alignment error was developed early in the program. And the allocation was used to guide the design. Though testing the surface roughness and figure error in visible light, the variation of diffraction encircled energy can be obtained by non-sequence model and Zernike coefficients brought into optical design software. The numerical results show that the effective RMS surface roughness of primary and secondary mirrors are 0.49nm and 0.40nm in the spatial frequency from 1/D (D is the diameter of the mirror) to 1/λ (λ is an incident wavelength). And the effects of the surface roughness are both less than 0.1″. The figure error of the primary and secondary mirrors are 0.009λ and 0.007λ (Λλ=632.8nm). The resolution errors which were brought by the figure error are 0.33″ and 0.16″. Then the effect of alignment error on angular resolution was gotten by testing visual resolution. Finally the angular resolution in ultraviolet band can be calculated. The focal length of Lyman-α ultraviolet telescope is 2000mm and the pixel size of detector is 14μm. So the pixel resolution is 1.4″. Experimental results show that the angular resolution of Lyman-α ultraviolet telescope is 0.59″, which is approached to the estimate and meet the requirement.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jiang Kai, Bo Jiang, Kai Liu, Peipei Yan, Jing Duan, and Qiusha Shan "Resolution allocation and budget of the Lyman-α ultraviolet telescope", Proc. SPIE 10154, Advanced Optical Design and Manufacturing Technology and Astronomical Telescopes and Instrumentation, 101541C (19 October 2016); https://doi.org/10.1117/12.2246786
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ultraviolet telescopes

Optical design

Spatial resolution

RELATED CONTENT

A UV-visible prime focus camera for the Keck telescopes
Proceedings of SPIE (January 03 2020)
A novel mini-DAS module for submarine application
Proceedings of SPIE (October 10 2020)
LINC NIRVANA a Fizeau beam combiner for the Large...
Proceedings of SPIE (February 21 2003)
Design and development of the SIMBOL X hard x ray...
Proceedings of SPIE (July 15 2008)

Back to Top