Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Flow cytometric separation of spectrally overlapping fluorophores using multifrequency fluorescence lifetime analysis

[+] Author Affiliations
Patrick L. Jenkins, Alexandra Arteaga, Jessica P. Houston

New Mexico State Univ. (USA)

James P. Freyer

Los Alamos National Lab. (USA)

Mark S. Naivar

DarklingX , LLC (USA)

Proc. SPIE 7902, Imaging, Manipulation, and Analysis of Biomolecules, Cells, and Tissues IX, 790216 (February 22, 2011); doi:10.1117/12.875627
Text Size: A A A
From Conference Volume 7902

  • Imaging, Manipulation, and Analysis of Biomolecules, Cells, and Tissues IX
  • Daniel L. Farkas; Dan V. Nicolau; Robert C. Leif
  • San Francisco, California, USA | January 22, 2011

abstract

Digital excited state lifetime measurements in cytometry were performed on multi-tagged Chinese Hamster Ovary (CHO) cells in order to discriminate between spectrally overlapping fluorescent species. Fluorescence lifetime was determined through digital Fourier analysis with a specialized data acquisition system subsequent to multi-frequency intensity modulation by a solid-state laser excitation source. This work demonstrates that square wave modulation coupled with digital lifetime signal processing can lead to separation of ethidium bromide (EB) and propidium iodide (PI), in cells stained with both dyes. By driving the square wave modulation of the laser at 2 MHz, we were able to access the multiple harmonics present within that wave. In an offline analysis, the phase differences of scatter and fluorescence channels were examined at each harmonic of the primary frequency. The phase difference revealed approximate fluorescence lifetimes of 27.1-ns and 13.0-ns for the EB and PI, respectively. Although the absolute lifetime of each species was not resolved to high accuracy, this work shows a clear separation of the lifetime value calculated at each harmonic. The calculated values that most closely corresponded to the single-dye and multiple-dye average lifetimes were found at the fundamental harmonic frequency (2 MHz) as well as the 4th harmonic (14MHz) frequency. At 2 and 14MHz the average lifetime was 27.1ns and 13.0ns, respectively.

© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

Patrick L. Jenkins ; James P. Freyer ; Mark S. Naivar ; Alexandra Arteaga and Jessica P. Houston
"Flow cytometric separation of spectrally overlapping fluorophores using multifrequency fluorescence lifetime analysis", Proc. SPIE 7902, Imaging, Manipulation, and Analysis of Biomolecules, Cells, and Tissues IX, 790216 (February 22, 2011); doi:10.1117/12.875627; http://dx.doi.org/10.1117/12.875627


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.