Optimizing source detector separation for an implantable perfusion and oxygenation sensor

[+] Author Affiliations
T. J. Akl, T. J. King, R. Long, M. J. McShane, G. L. Coté

Texas A&M Univ. (USA)

J. S. Baba, M. N. Ericson

Oak Ridge National Lab. (USA)

M. A. Wilson

Univ. of Pittsburgh (USA) and VA Pittsburgh Healthcare System (USA)

Proc. SPIE 7906, Optical Diagnostics and Sensing XI: Toward Point-of-Care Diagnostics; and Design and Performance Validation of Phantoms Used in Conjunction with Optical Measurement of Tissue III, 790605 (February 10, 2011); doi:10.1117/12.875731
Text Size: A A A
From Conference Volume 7906

  • Optical Diagnostics and Sensing XI: Toward Point-of-Care Diagnostics; and Design and Performance Validation of Phantoms Used in Conjunction with Optical Measurement of Tissue III
  • Robert J. Nordstrom; Gerard L. Coté
  • San Francisco, California, USA | January 22, 2011

abstract

Each year thousands of patients are added to the waiting list for liver transplants. The first 7-10 days after transplant have proven to be the most critical in patient recovery and it is hypothesized that monitoring organ vital signals in this period can increase patient and graft survival rates. An implantable sensor to monitor the organ perfusion and oxygenation signals following surgery is being developed by our group. The sensor operates based on measuring diffuse reflection from three light emitting diodes (735, 805 and 940 nm). In this work the optimal source detector spacing to maximize oxygenation signal level is investigated for a portal vein model. Monte Carlo simulations provided signal levels and corresponding penetration depths as a function of separation between a point optical source and detector. The modeling results indicated a rapid decay in the optical signal with increasing distance. Through further analysis, it was found that there exists an optimal range of point source to detector spacing, between roughly 1 and 2 mm, in which the blood signal from the simulated portal vein was maximized. Overall, these results are being used to guide the placement and configuration of our probe for in vivo animal studies.

© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

T. J. Akl ; T. J. King ; R. Long ; J. S. Baba ; M. J. McShane, et al.
"Optimizing source detector separation for an implantable perfusion and oxygenation sensor", Proc. SPIE 7906, Optical Diagnostics and Sensing XI: Toward Point-of-Care Diagnostics; and Design and Performance Validation of Phantoms Used in Conjunction with Optical Measurement of Tissue III, 790605 (February 10, 2011); doi:10.1117/12.875731; http://dx.doi.org/10.1117/12.875731


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.