abstract

Reduction of image noise is an important goal in producing the highest quality medical images. A very important benefit of reducing image noise is the ability to reduce patient exposure while maintaining adequate image quality. Various methods have been described in the literature for reducing image noise by means of image processing, both deterministic and statistical. Deterministic methods tend to degrade image resolution or lead to artifacts or non-uniform noise texture that does not look "natural" to the observer. Statistical methods, including Bayesian estimation, have been successfully applied to image processing, but may require more time-consuming steps of computing priors. The approach described in this paper uses a new statistical method we have developed in our laboratory to reduce image noise. This approach, Correlated-Polarity Noise Reduction (CPNR), makes an estimate of the polarity of noise at a given pixel, and then subtracts a random value from a normal distribution having a sign that matches the estimated polarity of the noise in the pixel. For example, if the noise is estimated to be positive in a given pixel, then a random number that is also positive will be subtracted from that pixel. The CPNR method reduces the noise in an image by about 20% per iteration, with little negative impact on image resolution, few artifacts, and final image noise characteristics that appears "normal." Examples of the feasibility of this approach are presented in application to radiography and CT, but it also has potential utility in tomosynthesis and fluoroscopy.

© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

James T. Dobbins III and Jered R. Wells
"Correlated-polarity noise reduction: feasibility of a new statistical approach to reduce image noise", Proc. SPIE 7961, Medical Imaging 2011: Physics of Medical Imaging, 79610A (March 15, 2011); doi:10.1117/12.879076; http://dx.doi.org/10.1117/12.879076


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.