Detailed characterization of 2D and 3D scatter-to-primary ratios of various breast geometries using a dedicated CT mammotomography system

[+] Author Affiliations
Jainil Shah, Jan H. Pachon, Priti Madhav, Martin P. Tornai

Duke Univ. (USA) and Duke Univ. Medical Ctr. (USA)

Proc. SPIE 7961, Medical Imaging 2011: Physics of Medical Imaging, 796158 (March 16, 2011); doi:10.1117/12.878809
Text Size: A A A
From Conference Volume 7961

  • Medical Imaging 2011: Physics of Medical Imaging
  • Norbert J. Pelc; Ehsan Samei; Robert M. Nishikawa
  • Lake Buena Vista, Florida | February 12, 2011

abstract

With a dedicated breast CT system using a quasi-monochromatic x-ray source and flat-panel digital detector, the 2D and 3D scatter to primary ratios (SPR) of various geometric phantoms having different densities were characterized in detail. Projections were acquired using geometric and anthropomorphic breast phantoms. Each phantom was filled with 700ml of 5 different water-methanol concentrations to simulate effective boundary densities of breast compositions from 100% glandular (1.0g/cm3) to 100% fat (0.79g/cm3). Projections were acquired with and without a beam stop array. For each projection, 2D scatter was determined by cubic spline interpolating the values behind the shadow of each beam stop through the object. Scatter-corrected projections were obtained by subtracting the scatter, and the 2D SPRs were obtained as a ratio of the scatter to scatter-corrected projections. Additionally the (un)corrected data were individually iteratively reconstructed. The (un)corrected 3D volumes were subsequently subtracted, and the 3D SPRs obtained from the ratio of the scatter volume-to-scatter-corrected (or primary) volume. Results show that the 2D SPR values peak in the center of the volumes, and were overall highest for the simulated 100% glandular composition. Consequently, scatter corrected reconstructions have visibly reduced cupping regardless of the phantom geometry, as well as more accurate linear attenuation coefficients. The corresponding 3D SPRs have increased central density, which reduces radially. Not surprisingly, for both 2D and 3D SPRs there was a dependency on both phantom geometry and object density on the measured SPR values, with geometry dominating for 3D SPRs. Overall, these results indicate the need for scatter correction given different geometries and breast densities that will be encountered with 3D cone beam breast CT.

© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

Jainil Shah ; Jan H. Pachon ; Priti Madhav and Martin P. Tornai
"Detailed characterization of 2D and 3D scatter-to-primary ratios of various breast geometries using a dedicated CT mammotomography system", Proc. SPIE 7961, Medical Imaging 2011: Physics of Medical Imaging, 796158 (March 16, 2011); doi:10.1117/12.878809; http://dx.doi.org/10.1117/12.878809


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.