abstract

The use of standard instrumentation for the assessment of the respiration rate as of flow is an important goal in medicine. Spirometers, textile-based capacitive sensors or photopletismography are standard contact instrumentations used for such aim; the main drawback in the use of such instrumentations is the necessity to have a direct contact of the instrument with the patient. In this paper, we present an optical no-contact method for monitoring of both the respiration rate and flow. This method is based on the measurement of external chest wall movement by a laser Doppler vibrometer. The measurement procedure has already been demonstrated to be extremely well performing for what concern the monitoring of the cardiac activity. The proposed method can be operated at a distance of 1.5 m, on different point of the patient thoracic and abdominal area. We have monitored respiration rate and flow on 8 patients with a spirometer and simultaneously with the proposed noncontact measurement procedure. Bland-Altman analysis of the respiration rate measured with both instruments demonstrate a mean error on the determination of the respiration rate of < 1% and of the < 4% for the instantaneous flow. We also report a study on the optimal position on the thoracic area based on quality of the signal measured on the same population of subject.

© (2010) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Lorenzo Scalise ; Paolo Marchionni and Ilaria Ercoli
"A non-contact optical procedure for precise measurement of respiration rate and flow", Proc. SPIE 7715, Biophotonics: Photonic Solutions for Better Health Care II, 77150G (May 14, 2010); doi:10.1117/12.854482; http://dx.doi.org/10.1117/12.854482


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement

 

 

  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.