Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Approximations of noise structures in helical multi-detector CT scans: application to lung nodule volume estimation

[+] Author Affiliations
Rongping Zeng, Nicholas Petrick, Marios A. Gavrielides, Kyle J. Myers

U.S. Food and Drug Administration (USA)

Proc. SPIE 7624, Medical Imaging 2010: Computer-Aided Diagnosis, 762415 (March 09, 2010); doi:10.1117/12.844216
Text Size: A A A
From Conference Volume 7624

  • Medical Imaging 2010: Computer-Aided Diagnosis
  • Nico Karssemeijer; Ronald M. Summers
  • San Diego, California, USA | February 13, 2010

abstract

We have previously presented a match filtered (MF) approach for estimating lung nodule size from helical multi-detector CT (MDCT) images [1], in which we minimized the sum of squared differences between the simulated CT templates and the actual nodule CT images. The previous study showed the potential of this approach for reducing the bias and variance in nodule size estimation. However, minimizing SSD is not statistically optimal because the noise in 3D helical CT images is correlated. The goal of this work is to investigate the noise properties and explore several approximate descriptions of the three-dimensional (3D) noise covariance for more accurate estimates. The approximations include: variance only, noise power spectrum (NPS), axial correlation, two-dimensional (2D) in-plane correlation and fully 3D correlation. We examine the effectiveness of these second-order noise approximations by applying them to our volume estimation approach with a simulation study. Our simulations show that: the variance-based pre-whitening and axial pre-whitening perform very similar to the non-prewhitening case, with accuracy (measured in RMSE) differences within 1%; the NPS based pre-whitening performs slightly better, with a 4% decrease in RMSE; the in-plane pre-whitening and 3D fully pre-whitening perform best, with about a 10% decrease in RMSE over the non-prewhitening case. The simulation results suggest that the NPS, 2D in-plane and fully 3D prewhitening can be beneficial for lung nodule size estimation, albeit with greater computational costs in determining these noise characterizations.

© (2010) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.

Topics

Lung ; Sensors ; Simulations
Citation

Rongping Zeng ; Nicholas Petrick ; Marios A. Gavrielides and Kyle J. Myers
"Approximations of noise structures in helical multi-detector CT scans: application to lung nodule volume estimation", Proc. SPIE 7624, Medical Imaging 2010: Computer-Aided Diagnosis, 762415 (March 09, 2010); doi:10.1117/12.844216; http://dx.doi.org/10.1117/12.844216


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement

 

 

  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.