Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Cryogenic metrology for the James Webb Space Telescope Integrated Science Instrument Module alignment target fixtures using laser radar through a chamber window

[+] Author Affiliations
T. Hadjimichael, D. Kubalak, P. Davila, W. Eichhorn, E. Mentzell, R. Ohl

NASA Goddard Space Flight Ctr. (USA)

A. Slotwinski

Nikon Metrology, Inc. (USA)

B. Eegholm, J. Hayden

Sigma Space Corp. (USA)

G. Scharfstein

Flexure Engineering, LLC (USA)

R. Telfer

Orbital Sciences Corp. (USA)

Proc. SPIE 7793, Optical System Alignment, Tolerancing, and Verification IV, 77930B (September 03, 2010); doi:10.1117/12.862693
Text Size: A A A
From Conference Volume 7793

  • Optical System Alignment, Tolerancing, and Verification IV
  • José Sasián; Richard N. Youngworth
  • San Diego, California, United States | August 01, 2010

abstract

The James Webb Space Telescope Integrated Science Instrument Module utilizes two fixtures to align the Optical Telescope Element Simulator (OSIM) to the coordinate systems established on the ISIM and the ISIM Test Platform (ITP). These fixtures contain targets which are visible to the OSIM Alignment Diagnostics Module (ADM). Requirements on these fixtures must be met under ambient and cryogenic conditions. This paper discusses the cryogenic metrology involving Laser Radar measurements through a chamber window that will be used to link photogrammetry target measurements used during ISIM structure cryogenic verification and the ADM targets, including evaluation of distortion introduced from the window.

© (2010) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

T. Hadjimichael ; D. Kubalak ; A. Slotwinski ; P. Davila ; B. Eegholm, et al.
"Cryogenic metrology for the James Webb Space Telescope Integrated Science Instrument Module alignment target fixtures using laser radar through a chamber window", Proc. SPIE 7793, Optical System Alignment, Tolerancing, and Verification IV, 77930B (September 03, 2010); doi:10.1117/12.862693; http://dx.doi.org/10.1117/12.862693


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.