Application of the standard Hough-transform to high resolution MRI of human trabecular bone to predict mechanical strength

[+] Author Affiliations
Holger F. Bohm

Technische Univ. Muchen (Germany) and Max-Planck-Institut f?r extraterrestrische Physik (Germany)

Christoph Rath, Roberto A. Monetti, Ernst J. Rummeny, Thomas M. Link

Technische Univ. Munchen (Germany)

Dirk Muller

Technische Univ. Munchen (Germany) and Max-Planck-Institut f?r extraterrestrische Physik (Germany)

David Newitt, Sharmila Majumdar

Univ. of California/San Francisco (USA)

Proc. SPIE 5032, Medical Imaging 2003: Image Processing, 470 (May 16, 2003); doi:10.1117/12.481137
Text Size: A A A
From Conference Volume 5032

  • Medical Imaging 2003: Image Processing
  • Milan Sonka; J. Michael Fitzpatrick
  • San Diego, CA | February 15, 2003

abstract

In this study we introduce two non-linear structural measures based on the Standard Hough-Transform (SHT) that are applied to high resolution MR-images of human trabecular bone specimens in order to predict biomechanical properties. The results are compared to bone mineral density (BMD) and linear morphometric parameters. Axial MR-images (voxel-size: 117x156x300 mm3) of 33 human femoral and 10 spinal specimens are obtained using a 3D-gradient-echo-sequence. After measurement of BMD by quantitative computed tomography (QCT) all specimens are tested destructively for maximum compressive strength (MCS). The SHT is applied to the binarized and Sobel-filtered images and the peak-value (maxH) and its corresponding bin (posH) of the normalized Hough-spectrum are determined as well as linear measures (apparent bone fraction (app.BV/TV), apparent trabecular separation (app.Tb.Sp), apparent trabecular perimeter per unit area (app.Tb.Perim)). For the spinal [femoral] specimens, R2 for MCS vs. maxH is 0.72 (p=0.004) [0.49 (p<0.001)], R2 for MCS vs. posH is 0.56 (p=0.013) [0.55 (p<0.001)], and R2 for MCS vs. BMD is 0.43 (p=0.041) [0.72 (p<0.001)]. Correlations of the conventional, linear morphometric parameters and MCS are lower than those for the SHT-based measures or BMD, ranging from 0.20 (p=0.003) for app.BV/TV to 0.46 (p<0.001) for app.Tb.Sp. Prediction of MCS by maxH, posH, or BMD alone is improved by combination with the linear morphometric parameters in a linear regressional model (R2 =0.79). In conclusion, the biomechanical strength of human trabecular bone in vitro can effectively be predicted from High-Resolution MR-images by structural measures based on SHT. In the vertebral specimens these are superior to BMD or conventional structural measures in predicting bone strength.

© (2003) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Holger F. Bohm ; Christoph Rath ; Roberto A. Monetti ; Dirk Muller ; David Newitt, et al.
"Application of the standard Hough-transform to high resolution MRI of human trabecular bone to predict mechanical strength", Proc. SPIE 5032, Medical Imaging 2003: Image Processing, 470 (May 16, 2003); doi:10.1117/12.481137; http://dx.doi.org/10.1117/12.481137


Access This Article
Sign In to Access Full Content
Please Wait... Processing your request... Please Wait.
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
 

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement


Buy this article ($18 for members, $25 for non-members).
Sign In