Paper
22 December 2003 Self-calibration technique for transmitted wavefront measurements
Author Affiliations +
Abstract
Micro-optic components and subsystems are becoming increasingly important in optical sensors, communications, data storage, and many other diverse applications. In order to adequately predict the performance of the final system, it is important to understand how the optical elements affect the wavefront as it is transmitted through the system. The wavefront can be measured using interferometric means, however, both random and systematic errors contribute to the uncertainty of the measurement. If an artifact is used to calibrate the system it must itself be traceable to some external standard. Self-calibration techniques exploit symmetries of the measurement to separate the systematic errors of the instrument from the errors in the test piece. If the transmitted wavefront of a ball lens is measured in a number of random orientations and the measurements are averaged, the only remaining deviations from a perfect wavefront will be due to spherical aberration contributions from the ball lens and the systematic errors of the interferometer. If the radius, aperture, and focal length of the ball lens are known, the spherical aberration contributions can be calculated and subtracted, leaving only the systematic errors of the interferometer. This paper develops the theory behind the technique and describes the calibration of a micro-interferometer used to measure the transmitted wavefront error of micro-refractive lenses.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Brent C. Bergner and Angela Davies "Self-calibration technique for transmitted wavefront measurements", Proc. SPIE 5180, Optical Manufacturing and Testing V, (22 December 2003); https://doi.org/10.1117/12.506408
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Wavefronts

Calibration

Interferometers

Monochromatic aberrations

Objectives

Mirrors

Microscopes

RELATED CONTENT

Experimental results for absolute cylindrical wavefront testing
Proceedings of SPIE (September 05 2014)
The Shack Interferometer
Proceedings of SPIE (November 21 1977)
Diffraction reference wavefront laser interferometer
Proceedings of SPIE (January 13 1993)
Production Interferometric Testing Of Diamond-Turned Surfaces
Proceedings of SPIE (December 25 1979)
New interferometers for testing optics
Proceedings of SPIE (November 01 1997)
Improved calibration of an interference microscope
Proceedings of SPIE (October 22 2001)

Back to Top