Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Extended depth of focus intra-ocular lens: a solution for presbyopia and astigmatism

[+] Author Affiliations
Alex Zlotnik, Ido Raveh, Shai Ben Yaish, Oren Yehezkel

Xceed Imaging Ltd. (Israel)

Michael Belkin

Goldshleger Eye Research Institute, Tel-Aviv Univ. (Israel)

Zeev Zalevsky

Bar-Ilan Univ. (Israel)

Proc. SPIE 7550, Ophthalmic Technologies XX, 75500A (March 02, 2010); doi:10.1117/12.846682
Text Size: A A A
From Conference Volume 7550

  • Ophthalmic Technologies XX
  • Fabrice Manns; Per G. Söderberg; Arthur Ho
  • San Francisco, California | January 23, 2010

abstract

Purpose: Subjects after cataract removal and intra-ocular lens (IOL) implantation lose their accommodation capability and are left with a monofocal visual system. The IOL refraction and the precision of the surgery determine the focal distance and amount of astigmatic aberrations. We present a design, simulations and experimental bench testing of a novel, non-diffractive, non-multifocal, extended depth of focus (EDOF) technology incorporated into an IOL that allows the subject to have astigmatic and chromatic aberrations-free continuous focusing ability from 35cm to infinity as well as increased tolerance to IOL decentration. Methods: The EDOF element was engraved on a surface of a monofocal rigid IOL as a series of shallow (less than one micron deep) concentric grooves around the optical axis. These grooves create an interference pattern extending the focus from a point to a length of about one mm providing a depth of focus of 3.00D (D stands for Diopters) with negligible loss of energy at any point of the focus while significantly reducing the astigmatic aberration of the eye and that generated during the IOL implantation. The EDOF IOL was tested on an optical bench simulating the eye model. In the experimental testing we have explored the characteristics of the obtained EDOF capability, the tolerance to astigmatic aberrations and decentration. Results: The performance of the proposed IOL was tested for pupil diameters of 2 to 5mm and for various spectral illuminations. The MTF charts demonstrate uniform performance of the lens for up to 3.00D at various illumination wavelengths and pupil diameters while preserving a continuous contrast of above 25% for spatial frequencies of up to 25 cycles/mm. Capability of correcting astigmatism of up to 1.00D was measured. Conclusions: The proposed EDOF IOL technology was tested by numerical simulations as well as experimentally characterized on an optical bench. The new lens is capable of solving presbyopia and astigmatism simultaneously by providing focus extension of 3.00D under various illumination conditions, wavelengths and pupil diameters of the implanted lens without loss of energy at any of the relevant distances.

© (2010) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Alex Zlotnik ; Ido Raveh ; Shai Ben Yaish ; Oren Yehezkel ; Michael Belkin, et al.
"Extended depth of focus intra-ocular lens: a solution for presbyopia and astigmatism", Proc. SPIE 7550, Ophthalmic Technologies XX, 75500A (March 02, 2010); doi:10.1117/12.846682; http://dx.doi.org/10.1117/12.846682


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.