abstract

The technique of Laser Doppler Perfusion Imaging (LDPI) is widely used for determining cerebral blood flow or skin perfusion in the case of burns. The commonly used Laser Doppler Perfusion Imagers are scanning systems which point by point scan the area under investigation and use a single photo detector to capture the photoelectric current to obtain a perfusion map. In that case the imaging time for a perfusion map of 64 x 64 pixels is around 5 minutes. Disadvantages of a long imaging time for in-vivo imaging are the bigger chance of movement artifacts, reduced comfort for the patient and the inability to follow fast changing perfusion conditions. We present a Laser Doppler Perfusion Imager which makes use of a high speed CMOS-camera. By illuminating the area under investigation and simultaneously taking images at high speed with the camera, it is possible to obtain a perfusion map of the area under investigation in a shorter period of time than with the commonly used Laser Doppler Perfusion Imagers.

© (2007) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Matthijs J. Draijer ; Erwin Hondebrink ; Wiendelt Steenbergen and Ton G. van Leeuwen
"Laser Doppler Perfusion Imaging with a high-speed CMOS-camera", Proc. SPIE 6631, Novel Optical Instrumentation for Biomedical Applications III, 66310N (July 18, 2007); doi:10.1117/12.727807; http://dx.doi.org/10.1117/12.727807


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.