For practical use, the electrical field requirements of Electro Active Polymer (EAP) actuators have to be lowered down. Recently, we developed nano carbon filled polymeric films which can generate a large strain (30-50%) at moderate electrical field (less than 20 MV/m). Herein, the electrostrictive strain saturates versus electrical field and that the maximum strain depends strongly on the sample thickness. Combining polarization saturation effect and heterogeneities in the polymer thickness lead to a model that describes correctly the strain behavior versus electrical field, polymer thickness and frequency. A three-layer model was established which assumes that the polymer is not homogeneous along the thickness. Two outer and one inner layers exist, which must be formed during the polymer curing. It is considered that these layers have slightly different characteristics, such as permittivity. When the electrical field is input parallel to the polymer thickness, a different strain would take place in each layer according to the field distribution. Since the layers are attached together, the strain must be the same in each layer. Consequently stresses appear in the different layers. Introducing in this model a saturation of the polarization for high field leads to simulation results that fit well the experimental data.

© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

K. Yuse ; D. Guyomar and M. Kanda
"Thickness effects in electroactive polymers actuators: a simple explanation and modeling", Proc. SPIE 7984, Health Monitoring of Structural and Biological Systems 2011, 79841M (March 31, 2011); doi:10.1117/12.880754; http://dx.doi.org/10.1117/12.880754


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.