Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Guided wave interaction with aerospace aluminium stringer feet

[+] Author Affiliations
Keith Tiplady, Bruce W. Drinkwater

Univ. of Bristol (United Kingdom)

Christophe Paget

Airbus Operations Ltd. (United Kingdom)

Proc. SPIE 7984, Health Monitoring of Structural and Biological Systems 2011, 79842V (April 18, 2011); doi:10.1117/12.883127
Text Size: A A A
From Conference Volume 7984

  • Health Monitoring of Structural and Biological Systems 2011
  • Tribikram Kundu
  • San Diego, California, USA | March 06, 2011

abstract

Acoustic Emission has shown itself to be a valuable technology for reliably detecting damage initiation and growth in large structures. Monitoring of a structure, throughout its life, is possible with sparse sensor arrays. However aerospace structures can be geometrically complex and contain many structural features, the most common being stringers. Stringers are arranged in a way that they can span the length of the wings or fuselage, separated by less than 200mm in certain cases. Therefore it is almost inevitable that, for any reasonable sensor spacing, acoustic emission events propagating guided waves will interact with multiple stringers. A large aerospace aluminium panel is used to minimise the effects of edge reflections and to allow the two fundamental guided wave modes to separate before reception. It is shown that stringer foot height has a noticeable impact on guided wave propagation, for typical aerospace arrangements. A reduction in transmitted signal amplitude was noted as the stringer thickness was increased. However a local maximum was seen when the stringer foot thickness was equal to that of the plate thickness. This paper discusses quantitative analysis of stringer interaction with the fundamental guided wave modes. The effect of the stringer as a feature has been divided into three main interactions; stringer dimensions, coupling media and riveting. Stringer dimensions and coupling media interactions has been investigated here to quantify their effect on transmission and reflection of the fundamental guided wave modes.

© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

Keith Tiplady ; Bruce W. Drinkwater and Christophe Paget
"Guided wave interaction with aerospace aluminium stringer feet", Proc. SPIE 7984, Health Monitoring of Structural and Biological Systems 2011, 79842V (April 18, 2011); doi:10.1117/12.883127; http://dx.doi.org/10.1117/12.883127


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.