Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Reflective measurement of water concentration using millimeter wave illumination

[+] Author Affiliations
Shijun Sung, David Bennett, Zachary Taylor, Neha Bajwa, Priyamvada Tewari, Ashkan Maccabi

Univ. of California, Los Angeles (USA)

Martin Culjat, Warren Grundfest

Univ. of California, Los Angeles (USA) and Ctr. for Advanced Surgical and Interventional Technology (USA)

Rahul Singh

Ctr. for Advanced Surgical and Interventional Technology (USA)

Proc. SPIE 7984, Health Monitoring of Structural and Biological Systems 2011, 798434 (April 18, 2011); doi:10.1117/12.883257
Text Size: A A A
From Conference Volume 7984

  • Health Monitoring of Structural and Biological Systems 2011
  • Tribikram Kundu
  • San Diego, California, USA | March 06, 2011

abstract

THz and millimeter wave technology have shown the potential to become a valuable medical imaging tool because of its sensitivity to water and safe, non-ionizing photon energy. Using the high dielectric constant of water in these frequency bands, reflectionmode THz sensing systems can be employed to measure water content in a target with high sensitivity. This phenomenology may lead to the development of clinical systems to measure the hydration state of biological targets. Such measurements may be useful in fast and convenient diagnosis of conditions whose symptoms can be characterized by changes in water concentration such as skin burns, dehydration, or chemical exposure. To explore millimeter wave sensitivity to hydration, a reflectometry system is constructed to make water concentration measurements at 100 GHz, and the minimum detectable water concentration difference is measured. This system employs a 100 GHz Gunn diode source and Golay cell detector to perform point reflectivity measurements of a wetted polypropylene towel as it dries on a mass balance. A noise limited, minimum detectable concentration difference of less than 0.5% by mass can be detected in water concentrations ranging from 70% to 80%. This sensitivity is sufficient to detect hydration changes caused by many diseases and pathologies and may be useful in the future as a diagnostic tool for the assessment of burns and other surface pathologies.

© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Citation

Shijun Sung ; David Bennett ; Zachary Taylor ; Neha Bajwa ; Priyamvada Tewari, et al.
"Reflective measurement of water concentration using millimeter wave illumination", Proc. SPIE 7984, Health Monitoring of Structural and Biological Systems 2011, 798434 (April 18, 2011); doi:10.1117/12.883257; http://dx.doi.org/10.1117/12.883257


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.