Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Resonant grating biosensor platform design and fabrication

[+] Author Affiliations
Valerie Brioude, Rachida Saoudi, Daniele Blanc, Stephanie Reynaud

Univ. Jean Monnet Saint-Etienne (France) and LTSI-CNRS (France)

Svetlen Tonchev

Institute of Solid State Physics (Bulgaria)

Nikolai M. Lyndin

General Physics Institute (Russia)

James Molloy

Labsystems Affinity Sensors (United Kingdom)

Proc. SPIE 5252, Optical Fabrication, Testing, and Metrology, 209 (February 26, 2004); doi:10.1117/12.513695
Text Size: A A A
From Conference Volume 5252

  • Optical Fabrication, Testing, and Metrology
  • Roland Geyl; David Rimmer; Lingli Wang
  • St. Etienne, France | September 30, 2003

abstract

Grating coupled evanescent wave slab waveguide biosensors are now well established about twenty years after they were demonstrated. They usually rely upon mode excitation from the substrate side, providing a means to measure the bioreaction at the waveguide surface through the monitoring of the conditions of mode excitation. A new readout principle will be presented whereby the incident beam undergoes a sharp and high reflection while being trapped into the biomaterial loaded grating waveguide. The high index metal oxide waveguide and the grating are designed so that the evanescent wave sensitivity is maximum and the conditions for resonant reflection are fulfilled for both polarizations close to normal incidence. Under these conditions, the grating corrugation cannot be located on both sides of the waveguide, as usually preferred, since the grating strength of the TM polarization would be too low. The corrugation must therefore be at the analyte side of the metal oxide layer ; this calls for a specific grating fabrication technology. The option retained for low cost manufacturing is that of wet etching of Ta2O5. This is quite a challenging problem since there is no wet etchant of high density Ta2O5 which does not dissolve standard photoresist, and since the isotropy of wet etching is likely to smooth out the required short period corrugation by underetching. This paper describes the rationale of the design of the reflection interrogation scheme and brings the experimental evidence of the effect obtained on wet etched sensor platforms.

© (2004) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Valerie Brioude ; Rachida Saoudi ; Daniele Blanc ; Stephanie Reynaud ; Svetlen Tonchev, et al.
"Resonant grating biosensor platform design and fabrication", Proc. SPIE 5252, Optical Fabrication, Testing, and Metrology, 209 (February 26, 2004); doi:10.1117/12.513695; http://dx.doi.org/10.1117/12.513695


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.