abstract

According to the energy ratio value of multi-band radiating from the measured surface, the 'true' temperature can be calculated by multi-band pyrometer. Multi-band pyrometer has many advantages: it can hardly be affected by the emission of measured surface and the environment radiation, and it has higher Signal-to-Noise Ratio and higher temperature measurement accuracy. This paper introduces the principle of a multi-band pyrometer and the uncertainty of measurement result is evaluated by using Monte-Carlo Method (MCM). The result shows that the accuracy of effective wavelength is the largest source of uncertainty and the other main source is reference temperature. When using ordinary blackbody furnace with continuous temperature, which can provide reference temperature and calibrate effective wavelength, the uncertainty component is 2.17K and 2.48K respectively. The combined standard uncertainty is 3.30K. A new calibration method is introduced. The effective wavelength is calibrated by monochromator, and the reference temperature is provided by fixed point black body furnace. The uncertainty component is decreased to 0.73K and 0.12K respectively. The measurement uncertainty is decreased to 0.74K. The temperature measurement accuracy is enhanced.

© (2010) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Yongjun Yang ; Xuecong Zhang ; Jing Cai and Zhongyu Wang
"Multi-band pyrometer uncertainty analysis and improvement", Proc. SPIE 7997, Fourth International Seminar on Modern Cutting and Measurement Engineering, 79971O (May 26, 2011); doi:10.1117/12.888618; http://dx.doi.org/10.1117/12.888618


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.