Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

A novel method for field complete parameters calibration of stereo vision sensor

[+] Author Affiliations
Bin Wu, Qingze Gao, Hongyan Zhu

Tianjin Univ. (China)

Proc. SPIE 7997, Fourth International Seminar on Modern Cutting and Measurement Engineering, 79972E (May 26, 2011); doi:10.1117/12.885870
Text Size: A A A
From Conference Volume 7997

  • Fourth International Seminar on Modern Cutting and Measurement Engineering
  • Jiezhi Xin; Lianqing Zhu; Zhongyu Wang
  • Beijing, China | December 10, 2010

abstract

To meet the need of high precision vision measurement, a novel method for field complete parameters calibration of stereo vision sensor is presented based on the two-dimensional target with unknown motion. Method: Firstly, according to the perspective projection model of camera and its coordination's relationship, the measurement math model is set up for stereo vision sensor. Secondly, the precision parameters of camera are calibrated with Zhang's camera calibration method based on planar target and the initial transition matrix of stereo vision sensor can be got. Finally, with the 3D measurement math model of stereo vision sensor and Levenberg-Marquardt method, the optimized parameters of stereo vision sensor are achieved. Result: Based on the above calibration method and two-dimensional target with unknown motion, the complete parameters of stereo vision sensor (including the camera's parameters and the transition matrix between two cameras) are calibrated. Experiments show that the relative error of distance measurement is less than 1.6% using a calibrated stereo vision sensor. Conclusion: The method is simple and convenient, with better efficiency, lower labour intensity and higher precision.

© (2010) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Bin Wu ; Qingze Gao and Hongyan Zhu
"A novel method for field complete parameters calibration of stereo vision sensor", Proc. SPIE 7997, Fourth International Seminar on Modern Cutting and Measurement Engineering, 79972E (May 26, 2011); doi:10.1117/12.885870; http://dx.doi.org/10.1117/12.885870


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.