Image quality in digital phase contrast imaging using a tungsten anode x-ray tube with small focal-spot size

[+] Author Affiliations
Hiromu Ohara, Chika Honda, Akira Ishisaka, Fumio Shimada

Konica Corp. (Japan)

Proc. SPIE 4682, Medical Imaging 2002: Physics of Medical Imaging, 713 (May 2, 2002); doi:10.1117/12.465619
Text Size: A A A
From Conference Volume 4682

  • Medical Imaging 2002: Physics of Medical Imaging
  • Larry E. Antonuk; Martin J. Yaffe
  • San Diego, CA | February 23, 2002

abstract

Phase contrast x-ray imaging has been studied intensively using x-rays from synchrotron radiation and micro-focus x- ray rubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using practical x-ray tubes with small focal spot sizes. In a previous study, we identified the radiographic conditions for phase contrast magnification mammography with screen-film systems, where the edge effect due to phase contrast outweighs the geometrical unsharpness introduced by the 0.1mm-focal spot of a molybdenum-anode x-ray tube. In the present study, phase contrast images of a hand and a chest phantoms were obtained using computed radiography and a geometrical magnification of two using a tungsten-anode x- ray tube with a 0.1mm-focal spot. The digital images were printed so that objects were reproduced at their original size. Compared to conventional digital contact images obtained at the same x-ray dose, the life-sized digital phase contrast x-ray images displayed improved sharpness and resolution, and reduced grain. We describe the empirical results of digital phase contrast imaging, and discuss these performance improvements through simulation including x-ray scatter.

© (2002) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Hiromu Ohara ; Chika Honda ; Akira Ishisaka and Fumio Shimada
"Image quality in digital phase contrast imaging using a tungsten anode x-ray tube with small focal-spot size", Proc. SPIE 4682, Medical Imaging 2002: Physics of Medical Imaging, 713 (May 2, 2002); doi:10.1117/12.465619; http://dx.doi.org/10.1117/12.465619


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.