Paper
7 February 2006 Utilization of magnetorheological finishing as a diagnostic tool for investigating the three-dimensional structure of fractures in fused silica
Author Affiliations +
Abstract
We have developed an experimental technique that combines magnetorheological finishing (MRF) and microscopy to examine fractures and/or artifacts in optical materials. The technique can be readily used to provide access to, and interrogation of, a selected segment of a fracture or object that extends beneath the surface. Depth slicing, or cross-sectioning at selected intervals, further allows the observation and measurement of the three-dimensional nature of the sites and the generation of volumetric representations that can be used to quantify shape and depth, and to understand how they were created, how they interact with surrounding material, and how they may be eliminated or mitigated.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Joseph A. Menapace, Pete J. Davis, William A. Steele, Lana L. Wong, Tayyab I. Suratwala, and Philip E. Miller "Utilization of magnetorheological finishing as a diagnostic tool for investigating the three-dimensional structure of fractures in fused silica", Proc. SPIE 5991, Laser-Induced Damage in Optical Materials: 2005, 599102 (7 February 2006); https://doi.org/10.1117/12.638840
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Silica

Magnetorheological finishing

Surface finishing

Refractive index

Polishing

Photomicroscopy

Statistical analysis

RELATED CONTENT