Paper
17 January 2002 Infrared hyperspectral imaging Fourier transform and dispersive spectrometers: comparison of signal-to-noise-based performance
Lee W. Schumann, Terrence S. Lomheim
Author Affiliations +
Abstract
We compare the signal-to-noise ratio (SNR) based performance of scanning dispersive and staring (Michelson interferometer based) Fourier transform spectrometer approaches to hyperspectral infrared imaging. The information collected by the focal planes of these two spectrometer types is very different. In the scanning dispersive spectrometer, the 2-D focal plane array (FPA) collects spatial information in one direction and spectral information in the other, while the second spatial dimension is swept out in time by the scanning mechanism. The Fourier transform spectrometer 2-D focal plane array acquires 2-D spatial information while the spectrum (interferogram) is swept out in time. The formation of the signal and propagation of noise from the focal plane data collection to the final hyperspectral data cube are significantly different for each type of instrument, and distinct signal and noise models apply to each. Using the noise equivalent spectral radiance (NESR)as a figure of merit, we compare the performance of the two types of instrument with the same optical system, equal spatial resolution, image area, spectral resolution, spectral span, and imaging time. Under photon noise limited conditions (for each instrument), which are made possible by the proper design of modern infrared focal plane arrays, the traditional multiplex (Fellgett) and throughput (Jacquinot) advantages associated with non-imaging Fourier transform spectrometers vanish for reasons that will be made clear in the paper. We discuss 2-D focal plane array characteristics for each instrument, such as frame rate, dynamic range, etc. and show why they are so different (by design) between these two instruments. Finally, the consequences of the signal processing requirements implied by the two instruments are summarized.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lee W. Schumann and Terrence S. Lomheim "Infrared hyperspectral imaging Fourier transform and dispersive spectrometers: comparison of signal-to-noise-based performance", Proc. SPIE 4480, Imaging Spectrometry VII, (17 January 2002); https://doi.org/10.1117/12.453326
Lens.org Logo
CITATIONS
Cited by 26 scholarly publications and 2 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Spectrometers

Staring arrays

Sensors

Signal to noise ratio

Fourier transforms

Interference (communication)

Spectral resolution

Back to Top