19 June 1998 Orientation and elongation of RBC in Searle flow in relation to forward scattering
Rainer Bayer, Markus Grewling, Thomas Wimmer, Alexander V. Priezzhev
Author Affiliations +
Proceedings Volume 3252, Optical Diagnostics of Biological Fluids III; (1998) https://doi.org/10.1117/12.311899
Event: BiOS '98 International Biomedical Optics Symposium, 1998, San Jose, CA, United States
Abstract
It is well accepted, that in whole blood as well as in blood suspensions light transmission increases, when shear stress is applied. Up to now it is not clear to what extent the changes in forward scattering are related to the orientation of the RBC in flow or to their elongation. If the latter would be true, forward scattering could be used as a simple parameter for RBC deformability. For our present investigation we used the method of laser diffraction in combination with image analysis to determine RBC elongation. Simultaneously forward scattering was measured by a photo detector, placed in the center of the non-diffracted laser beam. When slowly increasing the shear stress from 0 - 500 dyn/cm2 the light intensity measured by the photo detector first increased steeply, reaching a maximum of transmission at about 25 dyn/cm2, followed by a mono-exponential (elongation related) decay, reaching a 'steady state' at shear stresses producing maximum elongation (450 - 500 dyn/cm2). But, the decrease of transmission was only present, if the hematocrit (HCT) of the sample was greater than 0.5%. At a HCT less than or equal to 0.5%, only an exponential increase of transmission was detected, reaching a 'steady state' at about 25 dyn/cm2. In the apparatus used, the orientation of RBC is complete, if a shear stress of 15 to 25 dyn/cm2 is applied. Hence, at low shear stresses the increase of transmission is a consequence of RBC orientation. At low HCT, RBC-elongation (due to shear stresses between 25 - 500 dyn/cm2) does not influence forward scattering. The elongation related decrease of light transmission observed at high HCT (1% - 6%) may be explained by an increase of the area of deformed RBC, promoting the formation of additional cell layers. As a consequence multiple scattering will reduce transmission. Alternatively, during RBC-elongation the cross section of interaction, comprising absorption and scattering, may be altered.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Rainer Bayer, Markus Grewling, Thomas Wimmer, and Alexander V. Priezzhev "Orientation and elongation of RBC in Searle flow in relation to forward scattering", Proc. SPIE 3252, Optical Diagnostics of Biological Fluids III, (19 June 1998); https://doi.org/10.1117/12.311899
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scattering

Blood

Sensors

Light scattering

Diffraction

Laser scattering

Error analysis

Back to Top