Paper
1 July 1990 W. M. Keck Telescope segmented primary mirror active control system
Richard C. Jared, A. A. Arthur, S. Andreae, A. K. Biocca, Richard W. Cohen, Josep M. Fuertes, J. Franck, George Gabor, Jorge Llacer, Terry S. Mast, John D. Meng, Tom L. Merrick, Robert H. Minor, James Truman Nelson, M. Orayani, P. Salz, Barbara A. Schaefer, Chris Witebsky
Author Affiliations +
Abstract
The ten meter diameter primary mirror of the W. M. Keck Telescope is a mosaic of thirty-six hexagonal mirrors. An active control system stabilizes the primary mirror. The active control system uses 168 measurements of the relative positions of adjacent mirror segments and 3 measurements of the'primary mirror position in the telescope structure to control the 108 degrees of freedom needed to stabilize the figure and position of the primary mirror. The components of the active control system are relative position sensors, electronics, computers, actuators that position the mirrors, and software. The software algorithms control the primary mirror, perform star image stacking, emulate the segments, store and fit calibration data, and locate hardware defects.
© (1990) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Richard C. Jared, A. A. Arthur, S. Andreae, A. K. Biocca, Richard W. Cohen, Josep M. Fuertes, J. Franck, George Gabor, Jorge Llacer, Terry S. Mast, John D. Meng, Tom L. Merrick, Robert H. Minor, James Truman Nelson, M. Orayani, P. Salz, Barbara A. Schaefer, and Chris Witebsky "W. M. Keck Telescope segmented primary mirror active control system", Proc. SPIE 1236, Advanced Technology Optical Telescopes IV, (1 July 1990); https://doi.org/10.1117/12.19266
Lens.org Logo
CITATIONS
Cited by 40 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Actuators

Sensors

Mirrors

Control systems

Telescopes

Calibration

Image segmentation

RELATED CONTENT