15 April 1994 Two approaches in scanner-printer calibration: colorimetric space-based versus closed-loop
Victor Ostromoukhov, Roger David Hersch, Cecile Peraire, Isaac Amidror
Author Affiliations +
Proceedings Volume 2170, Device-Independent Color Imaging; (1994) https://doi.org/10.1117/12.173853
Event: IS&T/SPIE 1994 International Symposium on Electronic Imaging: Science and Technology, 1994, San Jose, CA, United States
Abstract
The present paper studies two different table-based approaches for the calibration of electronic imaging systems. The first approach, which is the classical one, uses the device-independent CIE-XYZ colorimetric space as an intermediate standard space. Input and output devices such as scanners, displays and printers are calibrated separately with respect to the objective CIE-XYZ space. The calibration process requires establishing a 3-dimensional mapping between scanner's device-dependent RGB pace and a device-independent colorimetric space such as CIE-XYZ. Measured samples belonging to the calibration set are used for splitting the colorimetric space into Delaunay tetrahedrons. The second approach, the so-called closed loop approach, calibrates directly scanner-printer pairs, without any reference to an objective colorimetric space. It enables a 3D mapping to be built between the scanner's RGB space and the printer's CMY space without requiring any colorimetric measurement. It offers very accurate calibrated output for input samples having the same characteristics (halftone dot, ink spectral reflectance) as the printed samples used for the calibration process. When the desktop scanners' RGB sensibilities are not a linear transform of the CIE x, y, z matching curves, an accurate calibration can only be made if input color patches are based on the same primary inks as the patches used for device calibration.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Victor Ostromoukhov, Roger David Hersch, Cecile Peraire, and Isaac Amidror "Two approaches in scanner-printer calibration: colorimetric space-based versus closed-loop", Proc. SPIE 2170, Device-Independent Color Imaging, (15 April 1994); https://doi.org/10.1117/12.173853
Lens.org Logo
CITATIONS
Cited by 9 scholarly publications and 9 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

RGB color model

Printing

Scanners

Error analysis

3D acquisition

3D printing

RELATED CONTENT


Back to Top