Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Two-channel optical imaging polarimeter

[+] Author Affiliations
Asoke K. Sen, S. N. Tandon

Inter Univ. Ctr. for Astronomy and Astrophysics (India)

Proc. SPIE 2198, Instrumentation in Astronomy VIII, 264 (June 1, 1994); doi:10.1117/12.176703
Text Size: A A A
From Conference Volume 2198

  • Instrumentation in Astronomy VIII
  • David L. Crawford; Eric R. Craine
  • Kailua, Kona, HI | March 13, 1994

abstract

The complexity of the structure of many astronomical objects (viz. galaxies, nebulae, comets etc.) is such that details of polarization frequently requires seeing limited resolution. A two channel imaging polarimeter has been described here which can provide seeing limited spatial resolution and highly accurate values of linear polarization by minimizing the harmful effects of atmospheric variations. This can be achieved by using a Wollaston prism analyzer to split a telescope image into two polarized components and simultaneously comparing them to eliminate effect due to atmospheric scintillation. The introduction of a grid at the focal plane, prevents the overlapping of o and e images on the CCD plane, where the image is refocussed. In order to keep the orientation of the two polarized components fixed in the instrument frame, the polarization vector of the image is modulated by mechanically rotating a half wave plate and readings are taken for several positions of the half wave plate to derive the polarization vector. We plan to use the above instrument at the cassegrain plane of 2.3 m V B telescope, India (f/13 beam) to carry out imaging polarimetry of extended astronomical objects. With 1000 secs. exposure time for each frame, on the GEC/EEF P8603A CCD chip, one can measure polarization values with an uncertainty of 0.3%, for the Seyfert N1068 (mv equals 17.5 per square arc sec) when observed in V band. This uncertainty is mainly dominated by photon count statistics. This instrument is presently being fabricated at Inter University Center for Astronomy and Astrophysics, Pune, India.

© (1994) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Asoke K. Sen and S. N. Tandon
"Two-channel optical imaging polarimeter", Proc. SPIE 2198, Instrumentation in Astronomy VIII, 264 (June 1, 1994); doi:10.1117/12.176703; http://dx.doi.org/10.1117/12.176703


Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Proceeding
Sign in or Create a personal account to Buy this proceeding ($15 for members, $18 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.