0

Full Content is available to subscribers

Subscribe/Learn More  >
Proceedings Article

Two-dimensional optoacoustic tomography: transducer array and image reconstruction algorithm

[+] Author Affiliations
Alexander A. Oraevsky, Valeri A. Andreev, Alexander A. Karabutov, Rinat O. Esenaliev

Univ. of Texas Medical Branch at Galveston (USA)

Proc. SPIE 3601, Laser-Tissue Interaction X: Photochemical, Photothermal, and Photomechanical, 256 (June 14, 1999); doi:10.1117/12.350007
Text Size: A A A
From Conference Volume 3601

  • Laser-Tissue Interaction X: Photochemical, Photothermal, and Photomechanical
  • Steven L. Jacques; Gerhard J. Mueller; Andre Roggan; David H. Sliney
  • San Jose, CA | January 23, 1999

abstract

Opto-acoustic tomography (OAT) utilizes laser pulses to create acoustic sources in tissue and wide-band detection of pressure profiles for the image reconstruction. A new laser optoacoustic imaging system (LOIS) for breast cancer detection and two-dimensional visualization is described. A Q-switched Nd:YAG laser was used for generation of opto-acoustic profiles in phantoms and tissues in vitro. Acoustic pulses were detected by a 12 element linear array of piezoelectric transducers. Each transducer was made of 0.5-mm thick PVDF slabs with dimensions of 4.3 mm X 12.5 mm. Signal-to-noise ratio was calculated and the sensitivity of optoacoustic system was evaluated. The axial (in-depth) resolution and the lateral resolution of the system were determined. The axial resolution of the receiving array was limited by its frequency band and was estimated to be approximately 1 mm. The lateral resolution was about 2.5 times the lateral dimension of the 'tumor' and defined by the finite aperture of the array and relatively large size of the single transducer. The time of full data acquisition was limited by the time allowed in clinical procedure of about 5 - 10 minutes. The procedure of signal processing is described. It includes high-pass signal filtering, compensation for acoustic diffraction, detection of the irradiated surface position and rejection of the reverberating signal. Radial back-projection algorithm for image reconstruction was developed and included in the computer code. Two-dimensional opto-acoustic images of simulated spheres and objects inside tissue phantoms are presented. The contrast of these images and limits of detection and localization of deeply embedded tumors are discussed.

© (1999) COPYRIGHT SPIE--The International Society for Optical Engineering. Downloading of the abstract is permitted for personal use only.
Citation

Alexander A. Oraevsky ; Valeri A. Andreev ; Alexander A. Karabutov and Rinat O. Esenaliev
"Two-dimensional optoacoustic tomography: transducer array and image reconstruction algorithm", Proc. SPIE 3601, Laser-Tissue Interaction X: Photochemical, Photothermal, and Photomechanical, 256 (June 14, 1999); doi:10.1117/12.350007; http://dx.doi.org/10.1117/12.350007


Access This Article
Sign In to Access Full Content
Please Wait... Processing your request... Please Wait.
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
 

Figures

Tables

NOTE:
Citing articles are presented as examples only. In non-demo SCM6 implementation, integration with CrossRef’s "Cited By" API will populate this tab (http://www.crossref.org/citedby.html).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement


Buy this article ($18 for members, $25 for non-members).
Sign In