13 October 1986 Dead-Time Effects In Pulse-Counting Digicon Detectors
Dennis C. Ebbets, Harry W. Garner
Author Affiliations +
Abstract
The High Resolution Spectrograph for the Hubble Space Telescope uses two pulse-counting Digicon detectors to record ultraviolet spectra in the wavelength range 1050 Å ( A< 3200 Å. One of the attractive features of the Digicon is the well behaved relationship between the measured count rate and the true photon arrival rate. At low rates the relationship is linear with unit slope and zero offset. At higher rates the intervals between photon arrivals become comparable to the response time of the electronics and not every pulse will be counted. This "paired-pulse" effect causes the relationship to depart from linearity at high count rates and must be corrected for during the reduction of raw data. In this paper we describe the characteristics of the pulse-counting circuits, and present two analytic equations which quantify the dead-time losses. During the ground-based calibration of the HRS observations of bright emission lines in the spectrum of an argon miniarc lamp were made to calibrate the non-linearity. By attenuating the light with neutral density filters the same spectrum could be recorded with input count rates ranging from 20 to 1.4 million counts per second per channel. The less attenuated spectra are severely distorted by the dead-time losses. Comparison with the undistorted low count rate data allows a detailed analysis to be made of the pulse counting characteristics over five decades of input event rates. The fitting formulas allow data with input rates up to 100000 counts per second to be linearized with no systematic errors. Our equations and calibration methods should be generally applicable to all kinds of multi-channel pulse counting detectors, which are becoming increasingly common in both ground and space based astronomical instruments.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Dennis C. Ebbets and Harry W. Garner "Dead-Time Effects In Pulse-Counting Digicon Detectors", Proc. SPIE 0627, Instrumentation in Astronomy VI, (13 October 1986); https://doi.org/10.1117/12.968141
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Calibration

Astronomy

Spectrographs

Diodes

Optical filters

Lamps

RELATED CONTENT

Mitigation of H2RG persistence with image illumination
Proceedings of SPIE (August 05 2016)
Software For Data Reduction From Digitized Detectors
Proceedings of SPIE (January 09 1984)
On-Board Autonomous Target Acquisition
Proceedings of SPIE (October 13 1986)
Solar ground calibration of ScaRaB: preliminary results
Proceedings of SPIE (September 15 1993)
Faint Object Spectrograph (FOS) Calibration
Proceedings of SPIE (November 16 1982)
Quantum efficiency characterization of scientific CCDs
Proceedings of SPIE (March 25 1996)

Back to Top