Presentation + Paper
6 July 2018 The Tomo-e Gozen wide field CMOS camera for the Kiso Schmidt telescope
Shigeyuki Sako, Ryou Ohsawa, Hidenori Takahashi, Yuto Kojima, Mamoru Doi, Naoto Kobayashi, Tsutomu Aoki, Noriaki Arima, Ko Arimatsu, Makoto Ichiki, Shiro Ikeda, Kota Inooka, Yoshifusa Ita, Toshihiro Kasuga, Mitsuru Kokubo, Masahiro Konishi, Hiroyuki Maehara, Noriyuki Matsunaga, Kazuma Mitsuda, Takashi Miyata, Yuki Mori, Mikio Morii, Tomoki Morokuma, Kentaro Motohara, Yoshikazu Nakada, Shin-Ichiro Okumura, Yuki Sarugaku, Mikiya Sato, Toshikazu Shigeyama, Takao Soyano, Masaomi Tanaka, Ken'ichi Tarusawa, Nozomu Tominaga, Tomonori Totani, Seitaro Urakawa, Fumihiko Usui, Junichi Watanabe, Takuya Yamashita, Makoto Yoshikawa
Author Affiliations +
Abstract
The Tomo-e Gozen is a wide-field high-speed camera for the Kiso 1.0-m Schmidt telescope, with a field-of-view of 20.7-deg2 covered by 84 chips of 2k x 1k CMOS image sensors with 19-μm pixels. It is capable to take consecutive images at 2-fps in full-frame read with an absolute time accuracy of 0.2 millisecond. The sensors are operated without mechanical coolers owing to a low dark current at room temperature. A low read noise of 2-e- achieves higher sensitivity than that with a CCD sensor in short exposures. Big data of 30-TBytes per night produced in the 2-fps observations is processed in real-time to quickly detect transient events and issue alerts for follow-ups.
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Shigeyuki Sako, Ryou Ohsawa, Hidenori Takahashi, Yuto Kojima, Mamoru Doi, Naoto Kobayashi, Tsutomu Aoki, Noriaki Arima, Ko Arimatsu, Makoto Ichiki, Shiro Ikeda, Kota Inooka, Yoshifusa Ita, Toshihiro Kasuga, Mitsuru Kokubo, Masahiro Konishi, Hiroyuki Maehara, Noriyuki Matsunaga, Kazuma Mitsuda, Takashi Miyata, Yuki Mori, Mikio Morii, Tomoki Morokuma, Kentaro Motohara, Yoshikazu Nakada, Shin-Ichiro Okumura, Yuki Sarugaku, Mikiya Sato, Toshikazu Shigeyama, Takao Soyano, Masaomi Tanaka, Ken'ichi Tarusawa, Nozomu Tominaga, Tomonori Totani, Seitaro Urakawa, Fumihiko Usui, Junichi Watanabe, Takuya Yamashita, and Makoto Yoshikawa "The Tomo-e Gozen wide field CMOS camera for the Kiso Schmidt telescope", Proc. SPIE 10702, Ground-based and Airborne Instrumentation for Astronomy VII, 107020J (6 July 2018); https://doi.org/10.1117/12.2310049
Lens.org Logo
CITATIONS
Cited by 9 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cameras

Sensors

Telescopes

CMOS sensors

Astronomy

Observatories

Data storage

RELATED CONTENT

An overview of the planned CCAT software system
Proceedings of SPIE (July 18 2014)
Development of a prototype of the Tomo e Gozen wide...
Proceedings of SPIE (August 09 2016)
ARNICA: the Arcetri Observatory NICMOS3 imaging camera
Proceedings of SPIE (October 20 1993)
Development and performance of a 128x128 2-um camera
Proceedings of SPIE (July 01 1990)
Instrumentation at the W. M. Keck Observatory
Proceedings of SPIE (July 09 2008)
OmegaCAM: wide-field imaging with fine spatial resolution
Proceedings of SPIE (September 30 2004)

Back to Top