The focal plane mask wheel sits in the input focus of the cryostat. It provides 16 user-selectable positions for masks (28x40 mm) used in observation. The key driver for this mechanism is the high repeatability (±2.5 μm) required, equivalent to ~1mas in the input focal plane. The IAC has previously designed, manufactured, tested and put in operation cryogenic wheels with high repeatability; however, the challenge of obtaining a wheel with such repeatability requires testing new concepts of detent positioning systems. The shutter allows for exposures shorter than the minimum read time of the near-IR detectors and is needed for any CCD observations with the visible cameras. A dual shutter design is needed to achieve the necessary open/close times (<20 ms), but this also provides some redundancy and a graceful failure mode for this critical device. To mitigate risks on the proper behaviour of a fast cryogenics shutter a prototype based on a simple concept has been manufactured. We present the design and results for the performed cryogenic tests of a mask wheel and a shutter prototypes that we have developed. |