Paper
27 November 1989 Low Noise Microchannel Plate Detectors For X-Ray Astronomy
Michael R. Garcia, Jon H Chappell, Stephen S. Murray, W. Bruce Feller, George W. Fraser
Author Affiliations +
Abstract
The dominant source of internal background in microchannel plate detectors is thought to be due to trace amount of ra-dioisotopes in the detector glass which decay through β-processes. Several manufacturers have begun programs to produce lead glass with greatly reduced amounts of radioisotopes in order to fabricate microchannel plates with lower internal background counting rates. Our laboratory measurements of such plates show that the background rates are substantially lower than in standard microchannel plates. The remaining background rate is consistent with the sum of the rates due to the residual trace level of radioisotopes, cosmic ray interactions in the microchannel plates, and a third, previously unrecognized component which is likely due to MeV γ-rays emitted by the laboratory concrete walls. We discuss the implications the measured background rates have for the sensitivity of the High Resolution Camera (HRC) to be flown on the U.S. Advanced X-ray Astrophysics Facility (AXAF). We compare these predicted rates with those measured in the High Resolution Imager (HRI) which was flown on the Einstein X-ray astronomy observatory.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Michael R. Garcia, Jon H Chappell, Stephen S. Murray, W. Bruce Feller, and George W. Fraser "Low Noise Microchannel Plate Detectors For X-Ray Astronomy", Proc. SPIE 1140, X-Ray Instrumentation in Medicine and Biology, Plasma Physics, Astrophysics, and Synchrotron Radiation, (27 November 1989); https://doi.org/10.1117/12.961809
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Microchannel plates

Sensors

Radioisotopes

X-rays

Glasses

X-ray astronomy

Manufacturing

RELATED CONTENT

Advances In Microchannel Plate Detectors
Proceedings of SPIE (December 21 1988)
After emission in microchannel plate detectors
Proceedings of SPIE (November 01 1990)
SPAN: a novel high-speed high-resolution position readout
Proceedings of SPIE (November 01 1990)
Properties of 100 mm X 100 mm triple stacks of...
Proceedings of SPIE (December 16 1993)
A large area detector proposed for the Large Observatory for...
Proceedings of SPIE (September 17 2012)

Back to Top