17 October 2022 Dark-field imaging on a clinical CT system: realization of Talbot-Lau interferometry in a gantry
Manuel Viermetz, Nikolai Gustschin, Clemens Schmid, Jakob Haeusele, Roland Proksa, Thomas Koehler, Franz Pfeiffer
Author Affiliations +
Proceedings Volume 12304, 7th International Conference on Image Formation in X-Ray Computed Tomography; 1230402 (2022) https://doi.org/10.1117/12.2646439
Event: Seventh International Conference on Image Formation in X-Ray Computed Tomography (ICIFXCT 2022), 2022, Baltimore, United States
Abstract
Computed tomography (CT) is a foundation of modern clinical diagnostics but it presently only retrieves information from X-rays attenuation. However, it is known that micro structural texture or porosity – which is well below the spatial resolution of CT – can be revealed by grating-based dark-field imaging. Diagnostic value of this sub-resolution tissue information has been demonstrated in pre-clinical studies on small-animal disease models and recently also in a first clinical radiography system.1 These studies show that dark-field imaging is particularly useful for early detection and staging of lung diseases. While dark-field CT is regularly realized in laboratory environment, the transfer to human scale and bringing it to clinical application poses several technical challenges. Switching from a step-and-shoot acquisition to a mode where the gantry and acquisition operate continuously as well as reducing scan times to below seconds and ensuring stability against vibrations are key concerns when it comes to the translation of the established laboratory dark-field technology to full-body medical CT. In,2 we recently demonstrated the first dark-field CT implementation, which collectively solves these roadblocks and therefore is a milestone in the development of clinical CT imaging. The prototype we present allows to reconstruct the attenuation and dark-field channels of a human thorax phantom from a one second long acquisition and covers a 45 cm diameter field of view. In this work, we present how the first dark-field CT prototype works and focus particularly on the technical design, optimized design of the gratings for CT application and the first characterization of the interferometer in the rotating gantry. We discuss which steps where particularly important for the realization and where we see potential for further improvements. These results provide key insights for future dark-field CT implementations.
© (2022) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Manuel Viermetz, Nikolai Gustschin, Clemens Schmid, Jakob Haeusele, Roland Proksa, Thomas Koehler, and Franz Pfeiffer "Dark-field imaging on a clinical CT system: realization of Talbot-Lau interferometry in a gantry", Proc. SPIE 12304, 7th International Conference on Image Formation in X-Ray Computed Tomography, 1230402 (17 October 2022); https://doi.org/10.1117/12.2646439
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Interferometers

X-ray computed tomography

Imaging systems

Signal attenuation

Visibility

X-ray sources

Scattering

Back to Top