Open Access Paper
17 October 2022 Soil matrix study using a hybrid a-Se/CMOS pixel detector for CT scanning
Akyl Swaby, Adam S. Wang, Michael G. Farrier, Weixin Cheng, Shiva Abbaszadeh
Author Affiliations +
Proceedings Volume 12304, 7th International Conference on Image Formation in X-Ray Computed Tomography; 123041E (2022) https://doi.org/10.1117/12.2646496
Event: Seventh International Conference on Image Formation in X-Ray Computed Tomography (ICIFXCT 2022), 2022, Baltimore, United States
Abstract
Computed tomography (CT) is a non-invasive means of localizing a region of interest within an object, which enables the investigation of soil distributions and localized flow processes within soil pore systems. CT scanning allows for cross-sectional successions that provide visibility within the environment of plant samples. Knowledge of the characteristics of the soil pore system is essential for evaluating various processes that take place between root-soil interactions. In this study, we investigate the potential application of a high-resolution amorphous selenium (a-Se) direct conversion detector on complementary metal-oxide-semiconductor (CMOS) readouts for micro-CT scanning of a soil matrix to image the status of aggregation and networks of pore spaces within intact soil. The combination of the intrinsic high spatial resolution of a-Se and small pixel CMOS readouts provide detailed visualization in the soil aggregates of the plant samples. The x-ray energy and plant soil thickness were varied during the investigation for imaging the root-soil. A 10 μm spatial resolution and noise limited performance of eight photons/pixel at 20 keV were achieved. High attenuation of x-rays in thick soil poses challenges however fine details are observable in thinner samples and care should be taken when choosing soil thickness and container material.
© (2022) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Akyl Swaby, Adam S. Wang, Michael G. Farrier, Weixin Cheng, and Shiva Abbaszadeh "Soil matrix study using a hybrid a-Se/CMOS pixel detector for CT scanning", Proc. SPIE 12304, 7th International Conference on Image Formation in X-Ray Computed Tomography, 123041E (17 October 2022); https://doi.org/10.1117/12.2646496
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-ray computed tomography

X-rays

Soil science

X-ray detectors

Spatial resolution

X-ray imaging

RELATED CONTENT

A study of EM failure in a micro scale Pb...
Proceedings of SPIE (September 11 2014)
Lab-based x-ray nanoCT imaging
Proceedings of SPIE (March 09 2017)
Evaluation of x ray detectors for dual modality CT SPECT...
Proceedings of SPIE (November 26 2002)
X ray tube based phase CT spectrum polychromatics and...
Proceedings of SPIE (March 16 2011)

Back to Top