12 May 1995 Monitoring of the quality of side-firing fibers using a special design power meter: Aquarius
Christiaan F. P. van Swol, Rudolf M. Verdaasdonck, Fidel A. Hermans, Remco J. van Vliet, Tom A. Boon
Author Affiliations +
Abstract
The treatment of Benign Prostatic Hyperplasia using the Nd:YAG laser is developing rapidly since the clinical introduction three years ago. In most cases a right angled fiber is used to deliver the laser light laterally towards the abundant prostatic tissue. The characteristics of these fibers differ, with regard to the angle at which the beam exits the fiber and the beam profile, resulting in a specific power density distribution on the tissue. During clinical use the characteristics of a fiber may change due to deterioration of the fiber tip. In this study the behavior of the various devices was monitored before and during clinical use with a special design power meter (Aquarius). The Aquarius measures the status of a right angled fiber in about fifteen seconds under clinical conditions, i.e., under water and at high input powers (40 - 80 Watt). In contrast with integrating sphere power meters specifically the primary beam is measured. The degree of deterioration of various fibers was quantified optically and thermally during clinical use. Devices using a metal mirror transmitted slightly less power than internal refraction based devices (80 versus 90 percent). The transmission of the various devices was not linear with the input power; at higher input powers (> 30 Watts) vapor bubbles, that developed at the tip of the device, decreased the transmission. During clinical use there was a large variation in decrease of transmission with regard to the total amount of energy transmitted through the fiber. However, at the end of a procedure the transmission had dropped to under 50%. The Aquarius is a powerful tool for evaluation and comparison of different laser prostatectomy devices both for clinical and experimental studies.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Christiaan F. P. van Swol, Rudolf M. Verdaasdonck, Fidel A. Hermans, Remco J. van Vliet, and Tom A. Boon "Monitoring of the quality of side-firing fibers using a special design power meter: Aquarius", Proc. SPIE 2395, Lasers in Surgery: Advanced Characterization, Therapeutics, and Systems V, (12 May 1995); https://doi.org/10.1117/12.209057
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical fibers

Power meters

Tissues

Sensors

Metals

Fiber lasers

Head

Back to Top