Paper
24 May 1996 Capability and integration test of the KHILS vacuum cryogenic chamber (KVACC)
Jack R. Lippert, Virgil G. Timms
Author Affiliations +
Abstract
The KVACC is a part of the Air Force Kinetic-kill vehicle Hardware-In-the-Loop Simulator facility whose purpose is to enable IR scene projection with a below ambient `cold' background for increased dynamic range and closer simulation realism. The geometric and spectral description of the system will be presented in the paper along with discussion as to operational details including cleanliness requirements, vacuum pump down time, and chill down rates using LN2. In addition, the lessons learned from integration checkout using a 512 X 512 Cryogenic Resistor array Infrared Scene Projector will be annotated. Upgrade potential and future plans, including Helium refrigerators will also be detailed.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jack R. Lippert and Virgil G. Timms "Capability and integration test of the KHILS vacuum cryogenic chamber (KVACC)", Proc. SPIE 2741, Technologies for Synthetic Environments: Hardware-in-the-Loop Testing, (24 May 1996); https://doi.org/10.1117/12.241125
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cryogenics

Projection systems

Mirrors

Helium

Resistors

Infrared radiation

Electronics

Back to Top