11 November 1996 MSX contamination experiment ion mass spectrometer observations during early operations
Robert E. Erlandson, Mark T. Boies, O. Manuel Uy, J. M. Grebowsky, Jack T. Coulson
Author Affiliations +
Abstract
Initial results from the midcourse space experiment (MSX) ion mass spectrometer (IMS) is presented. The IMS is designed to measure the concentration of contaminant and ambient ionospheric ions from 1 - 56 amu. In addition, the IMS is used to infer the floating potential of the satellite. Ambient ions observed in the IMS data include H+, He+, N+, and O+. The instrument was operated in a 'contaminant ion' mode during the early-operation phase (first seven days) in which the instrument was placed in its most sensitive state. This was done to search for contaminant ions, produced through charge exchange reactions between neutral water vapor and ionospheric O+ ions moving at 7.5 km/s relative to the satellite. Mass peaks near those expected for H2O+ were observed. Finally, the initial results on the satellite charge inferred from changes in the ion current collected as a function of the stopping potential are presented. It is found that the satellite potential floats between minus 6 to minus 10 V with respect to the plasma potential.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Robert E. Erlandson, Mark T. Boies, O. Manuel Uy, J. M. Grebowsky, and Jack T. Coulson "MSX contamination experiment ion mass spectrometer observations during early operations", Proc. SPIE 2864, Optical System Contamination V, and Stray Light and System Optimization, (11 November 1996); https://doi.org/10.1117/12.258311
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ions

Satellites

Space operations

Contamination

Spectroscopy

Plasma

Calibration