Paper
8 August 2001 Application of double hot-wire anemometer for the detection of the flow reversal
Jan Kielbasa
Author Affiliations +
Proceedings Volume 4516, Optoelectronic and Electronic Sensors IV; (2001) https://doi.org/10.1117/12.435902
Event: Optoelectronic and Electronic Sensors IV, 2000, Gliwice, Poland
Abstract
In this paper the rational description of the sensor constructed to detect the flow reversal has been presented. The sensor consists of two parallel heated wires the distance between them is appointed in such a manner that the thermal interaction of wires may be observed. In the sensor the wires are connected in series, and they are supplied by one constant temperature system. Consequently, the sum of resistances of wires is maintained to be constant. The difference of voltages referring to heated wires is recorded.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jan Kielbasa "Application of double hot-wire anemometer for the detection of the flow reversal", Proc. SPIE 4516, Optoelectronic and Electronic Sensors IV, (8 August 2001); https://doi.org/10.1117/12.435902