8 October 2001 Main design issues for embedding onto a wireless miniature robot a scanning tunneling positioning system capable of atomic resolution over a half-meter-diameter surface area
Sylvain M. Martel, Torsten Koker, Ian Warwick Hunter
Author Affiliations +
Proceedings Volume 4568, Microrobotics and Microassembly III; (2001) https://doi.org/10.1117/12.444146
Event: Intelligent Systems and Advanced Manufacturing, 2001, Boston, MA, United States
Abstract
Implementing instruments in the form of wireless miniature robots designed to operate at the atomic scale requires a positioning system capable of atomic resolution over a relatively large surface area. Interferometers or similar instruments are not adequate for such an environment because of the high probability that another robot obstructs the path of the laser during position measurement. As such, we have developed an infrared system based on a position sensing detection technique mounted on an x-y stepping stage where the position of an infrared signal transmitted upward from a miniature wireless robot can be detected with a resolution of +/- 1.585 micrometers over a 0.5 meter diameter circular surface. Although a fleet of miniature robots distributed over a relatively large area can be supported simultaneously, the system is still far from reaching positioning accuracy down to the level of a single atom. This is why we are embedding the capability to detect surface features down to the size of a single atom using scanning tunneling microscopy (STM) techniques onto the miniature robots. The dynamic range of the scanning piezo-tube is one of many design issues that must be carefully planned. For instance, the scanning system must be capable of detecting each atom in the scan path in order to determine the distance by counting the number of atoms while the maximum scan range must reach the discrimination level of the infrared positioning system despite many artifacts such as non-linearity errors and hysteresis. The feasibility and the design of such system are described.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Sylvain M. Martel, Torsten Koker, and Ian Warwick Hunter "Main design issues for embedding onto a wireless miniature robot a scanning tunneling positioning system capable of atomic resolution over a half-meter-diameter surface area", Proc. SPIE 4568, Microrobotics and Microassembly III, (8 October 2001); https://doi.org/10.1117/12.444146
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Scanning tunneling microscopy

Chemical species

Actuators

Infrared radiation

Electrodes

Infrared detectors

Tolerancing

RELATED CONTENT

Smart Sensors Why and when the origin was and...
Proceedings of SPIE (January 31 2014)
Uncooled IR imaging: technology for the next generation
Proceedings of SPIE (July 26 1999)
Infrared imaging system using nanocarbon materials
Proceedings of SPIE (May 07 2012)
Response Irregularities In Extrinsic Silicon Detectors
Proceedings of SPIE (December 23 1980)
Evolution Of Forward Looking Infrared
Proceedings of SPIE (March 12 1982)
Infrared internal emission detectors
Proceedings of SPIE (December 10 1992)

Back to Top