Abstract
1K × 1K Si:As Impurity Band Conduction (IBC) arrays have been developed by Raytheon Vision Systems (RVS) for the James Webb Space Telescope (JWST) Mid-Infrared Instrument (MIRI). The devices are also suitable for other low-background applications. The Si:As IBC detectors respond out to ~28 microns, covering an important mid-IR region beyond the 1-5 micron range covered by the JWST NIRCam and NIRSpec instruments. Due to high terrestrial backgrounds at the longer mid-IR wavelengths, it is very difficult to conduct ground-based observations at these wavelengths. Hence, the MIRI instrument on JWST can provide science not obtainable from the ground. A mid-infrared instrument aboard a cryogenic space telescope can have an enormous impact in resolving key questions in astronomy and cosmology. The greatly reduced thermal backgrounds achievable on a space platform (compared to airborne or ground-based platforms) allow for more sensitive observations of dusty young galaxies at high redshifts, star formation of solar-type stars in the local universe, and formation and evolution of planetary disks and systems. We describe results of the development of a new 1024 × 1024 Si:As IBC array with 25-micron pixels that responds with high quantum efficiency over the wavelength range 5 to 28 microns. The previous generation's largest, most sensitive IR detectors at these wavelengths were the 256 × 256/30-micron pitch Si:As IBC devices built by Raytheon for the SIRTF/IRAC instrument. JWST MIRI detector requirements will be reviewed and some model results for IBC device performance will be presented. The IBC detector architecture will be described and the SB305 Readout Integrated Circuit (ROIC), developed specifically for JWST MIRI, will be discussed. The SB305 ROIC utilizes a PMOS Source Follower per Detector (SFD) input circuit with a well capacity of about 2 × 105 electrons. The read noise is expected to be less than 20 e- rms with Fowler-8 sampling at an operating temperature of 7 K. Other features of the IBC array include 4 video outputs and a separate reference output with a frame rate of 0.37 Hz (2.7 sec frame time). Power dissipation is less than 0.5 mW at a 0.37 Hz frame rate. Reset modes include both global reset and reset by row (ripple mode). Reference pixels are built-in to the output data stream. The 1K × 1K IBC is packaged in a robust modular package that consists of a multilayer motherboard, silicon carbide (SiC) pedestal, and cable assembly with 51-pin MDM connectors. All materials of construction were chosen to match the thermal expansion coefficient of silicon to provide excellent module thermal cycle reliability for cycling between room temperature and 7 K.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Peter J. Love, Alan W. Hoffman, Nancy A. Lum, Ken J. Ando, William D. Ritchie, Neil J. Therrien, Andrew G. Toth, and Roger S. Holcombe "1Kx1K Si:As IBC detector arrays for JWST MIRI and other applications", Proc. SPIE 5499, Optical and Infrared Detectors for Astronomy, (29 September 2004); https://doi.org/10.1117/12.555219
Lens.org Logo
CITATIONS
Cited by 13 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

James Webb Space Telescope

Readout integrated circuits

Silicon carbide

Mid-IR

Quantum efficiency

Semiconducting wafers

RELATED CONTENT

HOT MWIR detectors on silicon substrates
Proceedings of SPIE (May 23 2018)
Space mid-IR detectors from DRS
Proceedings of SPIE (March 05 2003)
1024 x 1024 Si As IBC detector arrays for JWST...
Proceedings of SPIE (August 25 2005)

Back to Top