Paper
3 January 1986 All Single Mode Fiber Magnetic Field Sensor
M. Corke, P. M. Kopera, J. E. Moore, G. Ehrlich, M. Quaas, A. Matzkin-Bridger
Author Affiliations +
Abstract
The directional properties of a metallic glass sensing element have been investigated using an all fib pr Mach-Zender interferometer. A magnetic field sensitivity, at low frequency, of 2x10-te in the direction of the element was obtained with cross-sensitivities in the orthogonal directions being in the 0.1 Oe range.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
M. Corke, P. M. Kopera, J. E. Moore, G. Ehrlich, M. Quaas, and A. Matzkin-Bridger "All Single Mode Fiber Magnetic Field Sensor", Proc. SPIE 0566, Fiber Optic and Laser Sensors III, (3 January 1986); https://doi.org/10.1117/12.949803
Lens.org Logo
CITATIONS
Cited by 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Magnetic sensors

Magnetism

Interferometers

Sensors

Calibration

Fiber optics

Fiber optics sensors

RELATED CONTENT

Balancing A Fiber Optic Magnetic Gradiometer
Proceedings of SPIE (February 13 1990)
Fiber optic electrometer with mechanical resonator
Proceedings of SPIE (March 09 1994)
Fiber Optic Magnetic Sensor Development
Proceedings of SPIE (April 28 1987)
Closed-Loop Fiber-Optic Magnetometer/Gradiometer
Proceedings of SPIE (March 23 1988)

Back to Top