7 February 2007 The characterization of a phase contrast x-ray imaging prototype
Author Affiliations +
Abstract
Conventional x-ray imaging presents challenges for early detection and diagnosis, especially in areas such as mammography, where similar attenuation characteristics between malignant and normal breast tissue result in low contrast between them. An emerging technology called phase-contrast x-ray imaging has the potential to overcome this challenge by also incorporating phase shift effects, which contain more information than attenuation alone. The goal of this study was to verify through the accepted technique of contrast-detail analysis that the image quality provided by a phase-contrast prototype system is superior to that provided by a conventional imaging system. The use of a CDMAM phantom further reinforces the validity of the results, as this method has been proven to increase the accuracy, because it employs a four-alternative fixed choice method for the test objects instead of known locations. In the study, phasecontrast and conventional images of a CDMAM phantom were acquired and presented to observers for analysis. The corresponding contrast-detail curves comparing the systems demonstrate higher image quality produced by the phase-contrast system, an encouraging indication of the future of phase-contrast technology and a step forward in proving the feasibility of its introduction into a clinical environment.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Molly Donovan, Da Zhang, Wei R. Chen, and Hong Liu "The characterization of a phase contrast x-ray imaging prototype", Proc. SPIE 6436, Complex Dynamics and Fluctuations in Biomedical Photonics IV, 643608 (7 February 2007); https://doi.org/10.1117/12.712739
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-ray imaging

Image quality

Error analysis

Imaging systems

Signal attenuation

Image analysis

Prototyping

RELATED CONTENT

MTF evaluation of in-line phase contrast imaging system
Proceedings of SPIE (February 21 2017)
Fast decay solid state scintillators for high speed x ray...
Proceedings of SPIE (October 09 2019)
Low dose and scatter free cone beam CT imaging ...
Proceedings of SPIE (March 09 2012)
The Solar X ray Imager on GOES 13 design,...
Proceedings of SPIE (September 20 2007)

Back to Top