18 February 2009 Automated analysis of OCT images of the crystalline lens
Author Affiliations +
Proceedings Volume 7163, Ophthalmic Technologies XIX; 716313 (2009) https://doi.org/10.1117/12.809986
Event: SPIE BiOS, 2009, San Jose, California, United States
Abstract
Presbyopia is the age related, gradual loss of accommodation, mainly due to changes in the crystalline lens. As part of research efforts to understand and cure this condition, ex vivo, cross-sectional OCT images of crystalline lenses were obtained and analyzed to extract their physical and optical properties. The raw OCT images are distorted, as the probing beam passing through media of different refractive indices and refraction on curved surfaces. In a first step, various filters, edge detection and pattern matching methods are applied to isolate the edge contour. An ellipse is fitted to the lens outline to obtain central reference point for transforming the pixel data into the analysis coordinate system. This allows for the fitting of high order equation to obtain a mathematical description of the edge contour, which obeys constraints of continuity as well as zero to infinite surface slopes from apex to equator. Robustness of these algorithms are tested by analyzing the images at various contrast levels. Gradient refractive index of the lens is determined and the physical shape is reconstructed. In a further refinement, the refraction on the curved anterior surface is compensated to obtain the actual shape of the posterior surface. Once the physical shape is fully reconstructed, the optical properties are determined by fitting conic sections to both surfaces and calculating the power profile across the lens. The relative contribution of each of these refinement steps is investigated by comparing their influence on the effective power of the lens.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eon Kim, Klaus Ehrmann, Stephen Uhlhorn, David Borja, and Jean-Marie Parel "Automated analysis of OCT images of the crystalline lens", Proc. SPIE 7163, Ophthalmic Technologies XIX, 716313 (18 February 2009); https://doi.org/10.1117/12.809986
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Refractive index

Optical coherence tomography

Crystals

Edge detection

Image analysis

Optical properties

Refraction

RELATED CONTENT

Optical properties of KD*P modulators
Proceedings of SPIE (October 01 1990)
Optical path difference in a plane parallel uniaxial plate
Proceedings of SPIE (February 14 2005)
Polarization Ray Tracing In Birefringent Media
Proceedings of SPIE (June 29 1988)

Back to Top