Paper
9 March 2010 Performance evaluation of the non-linear and linear estimation methods for determining kinetic parameters in dynamic FDG-PET study
Xiaoqian Dai, Jie Tian, Zhe Chen
Author Affiliations +
Abstract
Dynamic positron emission tomography (PET) is a promising diagnostic tool to quantitatively predict biological and physiological changes in vivo through estimation of kinetic parameters. In this work, several popular linear and non-linear estimation methods for determining kinetic parameters using PET imaging with Fluorine-18 fluorodeoxyglucose ([18F]FDG) are compared and evaluated. The simulation studies are presented. The linear estimation methods include linear least squares (LLS), generalized linear least squares (GLLS) and total least squares (TLS), while the non-linear estimation methods include non-linear least squares (NLS), weighted nonlinear least squares using noisy tissue time activity data (WNLS-N), weighted non-linear least squares using noise-free tissue time activity data (WNLS-NF) and iteratively re-weighted non-linear least squares (IRWNLS). There are several findings: 1. Compared with non-linear estimation methods, GLLS performs well when noise level is low, but worse especially in determining k3 and k4 when noise level is high. What's more, GLLS does not show obvious advantage in running time. 2. The choice of weights plays an important role in nonlinear estimation methods. Weighting using noisy data should be avoided. WNLS-NF and IRWNLS perform best. Since the noise-free data can not be obtained in clinical and IRWNLS is time-consuming, NLS is most recommended. 3. Non-linear estimation methods are prone to produce lower-biased, higher-precision parameter estimates, however, also more easily affected by noise. Linear estimation methods are prone to be more biased, however, much more computational efficient and noise robust.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xiaoqian Dai, Jie Tian, and Zhe Chen "Performance evaluation of the non-linear and linear estimation methods for determining kinetic parameters in dynamic FDG-PET study", Proc. SPIE 7626, Medical Imaging 2010: Biomedical Applications in Molecular, Structural, and Functional Imaging, 76261A (9 March 2010); https://doi.org/10.1117/12.843796
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tissues

Positron emission tomography

Biological research

Plasma

Brain

Data modeling

Glucose

Back to Top