11 March 2010 On image rendering methods for improved image consistency in PACS environment
Zhimin Huo, Jane Zhang, Huihai Lu, John Wandtke, David Foos
Author Affiliations +
Abstract
The average workload per full-time equivalent (FTE) radiologist increased by 70% from1991-1992 to 2006- 2007. The increase is mainly due to the increase (34%) in the number of procedures, particularly in 3D imaging procedures. New technologies such as picture archiving and communication systems (PACS) and embodied viewing capability were accredited for an improved workflow environment leading to the increased productivity. However, the need for further workflow improvement is still in demand as the number of procedures continues growing. Advanced and streamlined viewing capability in PACS environment could potentially reduce the reading time, thus further increasing the productivity. With the increasing number of 3D image procedures, radiographic procedures (excluding mammography) have remained their critical roles in screening and diagnosis of various diseases. Although radiographic procedures decreased in shares from 70% to 49.5%, the total number has remained the same from 1991-1992 to 2006- 2007. Inconsistency in image quality for radiographic images has been identified as an area of concern. It affects the ability of clinicians to interpret images effectively and efficiently in areas where diagnosis, for example, in screening mammography and portable chest radiography, requires a comparison of current images with priors. These priors can potentially have different image quality. Variations in image acquisition techniques (x-ray exposure), patient and apparatus positioning, and image processing are the factors attributed to the inconsistency in image quality. The inconsistency in image quality, for example, in contrast may require manual image manipulation (i.e., windowing and leveling) of images to accomplish an optimal comparison to detect the subtle changes. We developed a tone-scale image rendering technique which improves the image consistency of chest images across time and modality. The rendering controls both the global and local contrast for a consistent look. We expect the improvement could reduce the window and level manipulation time required for an optimal comparison of priors and current images, thus improving both the efficiency and effectiveness of image interpretation. This paper presents a technique for improving the consistency of portable chest radiographic images. The technique is based on regions-of-interest (ROIs) to control both the local and global contrast consistency.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhimin Huo, Jane Zhang, Huihai Lu, John Wandtke, and David Foos "On image rendering methods for improved image consistency in PACS environment", Proc. SPIE 7628, Medical Imaging 2010: Advanced PACS-based Imaging Informatics and Therapeutic Applications, 762810 (11 March 2010); https://doi.org/10.1117/12.844621
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image processing

Image quality

Lung

Picture Archiving and Communication System

Chest

X-ray imaging

X-rays

Back to Top