Paper
13 October 2010 The influence of contaminated mirror on the flux distributions of stray radiation of infrared telescope systems
Pan He, Jing Xiao, Bin Zhang, Xiuwen Yao
Author Affiliations +
Proceedings Volume 7654, 5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Large Mirrors and Telescopes; 76540T (2010) https://doi.org/10.1117/12.867620
Event: 5th International Symposium on Advanced Optical Manufacturing and Testing Technologies, 2010, Dalian, China
Abstract
The existence of contaminated mirror in infrared telescope system not only reduces the contrast between objects and background, but also leads to the nonuniformity of the flux distribution of stray radiation on detector, resulting in great difficulty in obtaining and analyzing the target signal. In this paper, taking Cassegrain telescope as a typical example and using the optical analysis software, i.e., ASAP, the three-dimensional simulation model has also been built up. The self-generated thermal radiation flux and the flux distributions of stray radiation on the image plane have been simulated when the primary mirror under two cases, i.e., clean and local area contaminated. The influence of the size and position of the contaminated area on the uniformity of the flux distributions of stray radiation has been focused on discussion. The radiation flux and the flux distributions of stray radiation have been employed to evaluate the stray radiation performance of the system. The results indicate that the local area contamination on mirrors could change the uniformity of the flux distributions on the image plane and also degrade the stray radiation performance of the system, resulting in the influence on the detection and identification of the target. Consequently, it is of critical importance to keep the surface of optical elements clean, especially to avoid local area contamination on optics.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Pan He, Jing Xiao, Bin Zhang, and Xiuwen Yao "The influence of contaminated mirror on the flux distributions of stray radiation of infrared telescope systems", Proc. SPIE 7654, 5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Large Mirrors and Telescopes, 76540T (13 October 2010); https://doi.org/10.1117/12.867620
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Contamination

Mirrors

Sensors

Infrared telescopes

Scattering

Device simulation

3D modeling

RELATED CONTENT

Dual-waveband optical design for IR adaptive system
Proceedings of SPIE (November 20 2014)
CIAO: wavefront sensors for GRAVITY
Proceedings of SPIE (July 27 2016)
A Novel Double Imaging Camera (ANDICAM)
Proceedings of SPIE (March 07 2003)
Experimental Stray Light Measurements
Proceedings of SPIE (March 03 1981)
Infrared Sounder For Second Generation Meteosat
Proceedings of SPIE (April 13 1988)

Back to Top