Paper
31 March 2011 Synchronous monitoring of muscle dynamics and electromyogram
Author Affiliations +
Abstract
A non-intrusive novel detection scheme has been implemented to detect the lateral muscle extension, force of the skeletal muscle and the motor action potential (EMG) synchronously. This allows the comparison of muscle dynamics and EMG signals as a basis for modeling and further studies to determine which architectural parameters are most sensitive to changes in muscle activity. For this purpose the transmission time for ultrasonic chirp signal in the frequency range of 100 kHz to 2.5 MHz passing through the muscle under observation and respective motor action potentials are recorded synchronously to monitor and quantify biomechanical parameters related to muscle performance. Additionally an ultrasonic force sensor has been employed for monitoring. Ultrasonic traducers are placed on the skin to monitor muscle expansion. Surface electrodes are placed suitably to pick up the potential for activation of the monitored muscle. Isometric contraction of the monitored muscle is ensured by restricting the joint motion with the ultrasonic force sensor. Synchronous monitoring was initiated by a software activated audio beep starting at zero time of the subsequent data acquisition interval. Computer controlled electronics are used to generate and detect the ultrasonic signals and monitor the EMG signals. Custom developed software and data analysis is employed to analyze and quantify the monitored data. Reaction time, nerve conduction speed, latent period between the on-set of EMG signals and muscle response, degree of muscle activation and muscle fatigue development, rate of energy expenditure and motor neuron recruitment rate in isometric contraction, and other relevant parameters relating to muscle performance have been quantified with high spatial and temporal resolution.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
M. Zakir Hossain and Wolfgang Grill "Synchronous monitoring of muscle dynamics and electromyogram", Proc. SPIE 7984, Health Monitoring of Structural and Biological Systems 2011, 798419 (31 March 2011); https://doi.org/10.1117/12.880154
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Electromyography

Ultrasonics

Action potentials

Sensors

Signal detection

Nerve

Electrodes

RELATED CONTENT

The bionic man: Not too far away!
Proceedings of SPIE (May 18 2017)
Application of wavelets to electromyographic signals
Proceedings of SPIE (March 15 1994)
Analysis of synchrony in cultured neuronal network
Proceedings of SPIE (March 03 2006)
Optical stimulation of the auditory nerve effects of pulse...
Proceedings of SPIE (February 18 2011)
Laser stimulation of auditory neurons at high-repetition rate
Proceedings of SPIE (February 21 2007)

Back to Top