Paper
15 October 2012 Comparison of particle sampling results from tape lifts and solvent rinses
Author Affiliations +
Abstract
Historical experience and previously published papers have shown that contamination sampling techniques influence the cleanliness results of spaceflight hardware. Programs rely on this data to show that derived or contractual requirements are met at delivery. Particle sampling using tape lifts and rinses was performed on the James Webb Space Telescope (JWST) Primary Mirror Segment Assemblies (PMSAs) hardware. Sampling was performed on identical hardware with both sampling techniques. The hardware was sampled at comparable stages of assembly which provided hardware with similar levels of particulate contamination. Results from the two sampling techniques are compared. In one technique, sampling was performed by rinsing (with a hand-squeeze bottle with low pressure) followed by a tape lift; the other technique used a tape lift only. The relationship of particle size distribution, types of particles, level of particle contamination, and particle removal rate by sampling technique are examined. Comparison of the particle sampling results provides a basis for interpreting results depending on sampling techniques. Improving the contamination engineer’s ability to interpret results is particularly useful when hardware configuration or surface finish dictate which sampling technique can be used. When one can choose the sampling technique, the results of this study can provide guidance on which technique is more appropriate depending on the circumstances. Results show that tape lifts remove more particles than low pressure rinses; furthermore that tape lift only is better than the combined operation of a rinse closely followed by a tape lift. Results also indicate that further work should be performed on different surface finishes, rinsing techniques, and particulate contamination levels.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Joanne Egges, Genevieve Devaud, Christina M. Rockwell, and Bruce A. Matheson "Comparison of particle sampling results from tape lifts and solvent rinses", Proc. SPIE 8492, Optical System Contamination: Effects, Measurements, and Control 2012, 84920I (15 October 2012); https://doi.org/10.1117/12.932461
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Particles

Picture Archiving and Communication System

James Webb Space Telescope

Contamination

Aerospace engineering

Beryllium

Mirrors

Back to Top