|
1.IntroductionGreat attention has been paid in the past decade to flow velocity measurements in microscale miniaturized structures in the fields of chemical analysis and biological sciences. Development of microfabrication technologies for lab-on-a-chip devices has enabled the application of microfluidic systems in drug testing,1 sorting of cells,2 DNA characterization,3 polymerase chain reactions,4 and biochemical analyses. Currently, microchannels incorporating microfluidics have been reported to assist in vitro cell culture in tissue engineering.5, 6, 7 It is necessary to understand the flow patterns in these microchips to help engineers to improve the performance of fluidic systems as well as to enable the evaluation of mass-transport-limited reaction patterns. Another important subject is the measurement of flow profiles in living tissues and organisms. The investigation of blood flow in vivo can provide information about the environment of endothelial cells,8, 9, 10 a precondition for mimicking and optimizing the physiological conditions in culture systems. Various approaches have been proposed and applied to monitor the fluid flow in microscale systems and even animal bodies in the past decade including particle image velocimetry11 (PIV), laser speckle imaging,12 optical Doppler tomography,13 nuclear magnetic resonance (NMR) imaging.14 However, most of them are limited either in spatial resolution or in high concentration of larger probes. For example, PIV requires the use of a sufficient number of microbeads, which might cause severe obstruction of flow and distortion of the flow profile in these micrometer sized structures. An alternative for microfluid flow measurements is fluorescence correlation spectroscopy (FCS), which measures the time fluorescent molecules require to pass through a confocal observation volume.15, 16 FCS can work at very low concentrations of small fluorescent molecules with high spatial resolution, circumventing the problems of PIV. Its experimental validation particularly in flow was demonstrated in the transport of large protein units in plant cells,17 enhanced yellow fluorescent protein (EYFP) bacteria flowing in a capillary,18 and DNA molecules in a microfluidic channel3 but not in living tissues. In addition to single-point measurements, FCS has been extended to obtain flow profiles by positioning the observation volume point by point in a microfluidic channel,19 so as to acquire microfluid velocity images vertically and horizontally.20 However, the FCS probe volume is rotationally symmetric in the focal plane, thus no information about flow directions can be obtained. A rectangular or elliptical laser beam cross section was used, thus breaking the symmetry of the probe volume in the plane of focus.21 In these systems, the traveling time of molecules through the observation volume depends on the structural extension of the focal volume in flow direction and varies from a minimum, when the flow is parallel to the short axis, to a maximum, when the flow is along the long axis. However, the methods measure only different flowing times but not flow velocities because of the focal volume geometry, while the flow direction is still ambiguous since opposite flows cannot be distinguished. Their applications in biological tissues are limited for these strategies because the focal geometry can not be accurately characterized due to the refractive index distortion in biological specimens. The other improved schemes are dual-beam FCS (Ref. 22), coupled with techniques of two-color cross-correlation23 and time-delayed two-photon pulse excitation.24 But their drawbacks are low spatial resolution for directionality analysis and limited detection efficiency at large flow angles. No application of these two methods in practical systems for actual angle determination has been presented so far. Scanning FCS since its invention has been used for various biological applications.25, 26 Additionally, two-photon excitation improves its detection efficiency and accuracy.27 Recently, two kinds of scanning FCS techniques are reported to measure protein or molecule flow velocity, such as spatiotemporal image correlation spectroscopy28 (STICS) and circular scan FCS (so-called PSFCS; Ref. 29). In this paper, line-scan FCS is proposed for the analysis of flow profiles in microchannels and even living tissues. Here we present a modified laser scanning confocal microscope (LSCM) that enables FCS measurements and performs line-scan FCS as one of its functions. Under defined conditions, the line scans can be considered as quasisingle directional for FCS analysis. Hence, by linearly scanning the probe volume through the sample one introduces an external single directional “flow” into the microfluidic system without internal disruption. If the speeds of internal microfluid flow, external “flow” and the net flow are measured, the angles formed by external flow and internal microfluid flow can be calculated. Importantly, line-scan FCS has the advantage that the scanning speed is the key parameter to resolve flow directions, which is critical for the cases such as tissue measurements when the focus geometry is unknown. This method is verified by the investigations of flow profiles in a center-obstructed microchannel and applied to the determination of blood flow angles in small vessels in an immobilized living zebrafish embryo. 2.Theory2.1.FCS MeasurementsFCS measures temporal intensity fluctuations of fluorescent molecules caused by their dynamic processes, such as diffusion or flow, within a small open volume that is defined by a focused laser beam. The autocorrelation function (ACF) of the fluorescence fluctuation signal for pure 3-D diffusion is given by15, 30, 31 where is the number of molecules; is the diffusion time of molecules through the focal volume; is the relaxation time of the molecule from the triplet state to the ground state; is the fraction of the number of molecules in the triplet state; the structural parameter is defined as , an important factor to characterize the optical alignment; and and are its radial and axial extensions, defined as the distance from the focal point where the intensity has decreased by a factor of compared to the central intensity.2.2.FCS Flow AnalysisMeasurement of microfluid flow speeds by FCS was first described with the assumption that flow is uniform and single-directional in a plane perpendicular to the optical axis. The normalized ACF in the case for a single flow component coupled with free diffusion results in a one-flow model is16, 22 where is the traveling time of molecules through the focal volume. The flow speed is calculated as . Note that a single directional scan of the laser focus with constant velocity in a static solution will generate the same flow pattern25 [Eq. 2].2.3.Laser Focus Bidirectional ScansWhen two independent flow components are present in FCS measurements, the ACF can be expressed as a two-flow model [Eq. 3]. This situation usually arises only when the two flow components exist independently at different times, as is the case in an organism with a heart beat, where systolic and diastolic flow is different, or any system in which the flow is alternated between two different flows. This is also the case when, e.g., using bidirectional scans of a laser scanning confocal microscope with alternating forward and backward scans of different speeds. Under the assumption that the scan times are larger than the diffusion time ( , ), the forward and backward scans can be treated as independent. Therefore, the resulting ACF for laser bidirectional scans is represented by a two-flow model: where is the fraction of time the system experiences the flow with a characteristic flow time , and is the fraction of time the system experiences the flow with a characteristic flow time . For the case of the bidirectional scans, , where and represent the times during which the system experiences forward and backward scans.2.4.Analysis of Flow DirectionsAs illustrated in Fig. 1A , the laser beam is scanned at an angle of with respect to the flow direction in the microchannel. By considering the scanning laser focus as a reference, and assuming a constant scan speed in one direction, a schematic diagram of relative velocities can be drawn [Fig. 1B], where is the net velocity vector of the combined flows of and . The mathematical relationship of those three velocities can be defined by the equation as follows: Note that can be determined for a specific instrument by single-point FCS flow analysis in a solution without flow, can be measured in the flowing sample solution with a stationary laser focus, and is measured in the same flowing sample while linearly scanning the laser focus. With these three parameters known, the angle can be calculated.As long as the laser line scan direction is known, the flow angle can be determined as . This is true under the assumption that flow speed and direction in the sample does not vary significantly over the scanning distance. Therefore, the resolution of this method is limited by the length of the scan line.3.Experimental3.1.Optical System SetupA commercial LSCM (FV300, Olympus, Singapore) was modified and combined with FCS. For the FV300, a laser ( , Melles Griot, Singapore) is coupled into the scanning unit (Fig. 2 , dashed box) after passing through an optical fiber, and reflected by a mirror and an excitation dichroic mirror (488/543/633) into a pair of galvanometer scanning mirrors (G120DT, GSI Lumonics). After being scanned, the laser beam is directed into a water immersion objective [ , numerical aperture (NA) 1.2, Olympus, Singapore] by a reflective prism and focused into a small focal volume in the specimen. The fluorescence emitted from the sample is collected by the same objective, descanned, and focused again by a collecting lens into a confocal pinhole. A glass slab is used for light beam position alignment. A modified detection part (Fig. 2, solid box) for FCS was mounted on the top of the scanning unit. The fluorescence light after the confocal pinhole is imaged by a lens (Achromats , Linos, Goettingen, Germany), through an emission filter (580DF30, Omega, Brattleboro, Vermont, USA), into the active area of an avalanche photodiode (APD) in a single-photon-counting module (SPCM-AQR-14, Pacer Components, Berkshire, UK). The transistor-to-transistor logic (TTL) output signal from the APD is processed online by an autocorrelator (Flex02-01D, correlator.com, Zhejiang, China) to get an experimental ACF curve. Curve fitting is performed by a self-written program in Igor Pro (WaveMetrics, Lake Oswego, Oregon, USA). 3.2.Selective Scan LengthThe analog voltage, a saw tooth signal used to control the scanner to perform the line scan, was acquired and converted to a digital signal (DAQCard 1200, National Instruments Singapore). A self-written program (LabView, National Instruments Singapore) was used to create a TTL output pulse for each minima of the saw tooth signal to synchronize the data acquisition with the line scan. The arrival times of these TTL pulses marking the start of a scan line and the signals from the APD were simultaneously recorded by a counter/timer device (PCI-6602, National Instruments Singapore). The synchronization of the fluorescence signal with the scanner enables the accurate selection of data acquired during any specific phase of the line scan. The ACF data calculation and curve fitting were completed by programming in Igor Pro. 3.3.MicrochannelsTeflon is used to fabricate a microchannel mold with one inlet [Fig. 3A , point a] and two outlets [Fig. 3A, points b and c], its cross section is a rectangle of width and height. Prepolymer of polydimethylsiloxane (PDMS) (Sylgard 184, Dow-Corning, Midland, Michigan, USA) is poured over the molds and cured at overnight before peeling off. The PDMS membrane is oxidized in oxygen plasma for to be chemically bonded to a glass coverslip. To generate an obstruction flow pattern, a fiber with a radius of is inserted into the center of a microchannel after the fabrication process [Fig. 3A, point d]. A syringe pump (KDS100, Fisher Scientific, Singapore) is employed for the perfusion of probe solution into the microchannels through tubing and connectors. Different flow velocities in the microchannel can be induced by varying the syringe pump rates. 3.4.ZebrafishThe maintenance of zebrafish was based on the protocols in the zebrafish book.32 Briefly, a pair of AB wild-type zebrafish was crossed and their embryos were collected the next morning. The embryos were then incubated in egg water [ , Instant sea salts (Aquarium Systems, Inc.)] at for the optimal development, and after (hours postfertilization) PTU (0.003% 1-phenyl-2-thiourea in 10% Hank’s saline, Invitrogen, Singapore) was added to prevent pigmentation. Embryos were dechorionated at the time of and then anaesthetized by Tricaine (ethyl m-aminoboenzoate, Sigma, Singapore). The treated embryos were mounted in 0.5% low-melting-temperature agarose (Invitrogen, Singapore) in a glass bottom dish (GW-3512, WillCo-Wells, The Netherlands) for the following measurements. 3.5.ProceduresA dye solution ( , atto565, Sigma, Singapore) was prepared in deionized water as a probe for all flow measurements. Excitation was at a power of just before the objective provided by a laser . Line-scan speeds of different scan modes, such as fast, medium, and slow, were calibrated and measured in a static dye solution; various flow speeds induced by a syringe pump were obtained by single-point FCS measurements and the combined speeds of flow and scan were acquired by line-scan FCS. As a compromise of the accuracy and resolution, a slow scan line of , perpendicular to the channel wall, was selected for the applications of the method in flow velocity mapping in microchannels and zebrafish tissues. The acquisition time was for all measurements. The structural parameter , extracted from a calibration measurement, was the only parameter to be fixed for the following data fitting. 4.Results and Discussion4.1.Optical CalibrationsTo characterize the combination system, a probe solution of atto565 was sealed in a rubber-glass chamber and ACF curves at points were acquired by single-point FCS measurements. From the obtained contour figures of and (data not shown), the aberrations are found not to significantly affect the values of and in a circular area with a radius of , about 2/3 of the full field of view. The central point value of was , and the error for any measurement does not exceed 3.5%. The radial extension at the central point can be calculated as , where is calculated as , assuming that the diffusion coefficient of rhodamine 6G is [Ref. 30] and . The implication of this fact is that the focal volume defined by the laser beam does not vary greatly at different positions in a central area of diameter. 4.2.Fit Models and Line ScansThe confocal microscope FV300 has three bidirectional line-scan modes, namely, fast, medium, and slow. Time durations of these scan modes for one cycle are , , and , respectively, regardless of the lengths of the scan line, as determined from the scanning mirror voltages input by an oscilloscope. Three normalized ACF curves of line scans in the modes of fast, medium, and slow are shown in Fig. 4A . The shorter the scanning time, the faster will be the scan speeds, which is emphasized by a shorter decaying time in the ACF curve [ , Eq. 2]. Furthermore, the speed of a line scan is proportional to its length. The longer the line, the faster is the laser beam scan [Fig. 4B]. We use both a one-flow model [Eq. 2] and a two-flow model [Eq. 3] to fit the data, and fitting results are shown in Table 1 . From the values of , which is a good indicator of difference between the fitting functions and raw data,33, 34 we can see that for the medium and fast bidirectional line-scan modes, the fits tend to deviate more from the data. This is probably due to nonlinear behavior of the scan mirrors at the endpoints of the scan. Nevertheless, in all cases, the ratios of and are in good agreement with those of and for fast, medium, and slow scan modes as measured by the oscilloscope (Table 1, parentheses). Therefore, the scan speeds of forward and backward scans can be extracted by the two-flow fit model. To test which model is appropriate for a certain scan mode we calculated the level of significance that the two-flow model represents an actual improvement over the one-flow model by an test.35 For the fitting results shown in Table 1, the number of all data points is 550, and there are six free parameters for the one-flow fit model [Eq. 2] and eight free parameters for the two-flow model [Eq. 3] because the structural parameter was fixed in the fitting. The values from the test are calculated as 93.4% for fast, 74.9% for medium, and 81.1% for slow scan modes. The fact that the value is larger than 90% indicates that the two-flow fit model is applicable for the fast scans. For the medium and slow scans, the results show that the necessity of introducing the two-flow model is much less significant, and the one-flow model is acceptable for data fitting. This is probably due to their relatively large time ratios of forward scans over backward scans. In theory, the two-flow model can be simplified into a one-flow model only if , since for this case, the temporal intensity fluctuations are mostly caused by , i.e., by the forward scan. As an experimental verification, the Atto 565 solution was perfused into the microchannel at a pumping rate of , and the direction of the microchannel was manually adjusted to . Slow scan lines perpendicular to the flow axis with different lengths from to with and without flow were used to measure the net speeds and the scan speeds [Fig. 4C]. Flow angles determined by the one-flow and the two-flow models are plotted against the scan lengths [Fig. 4D]. From the graph, the net speeds obtained by the two-flow model are almost the same as those from the one-flow model, and the results of flow angles by the two fit models overlap without great differences. This agrees with our previous assumption that the one-flow model is suitable for the scans in medium or slow modes. Therefore, in the following we assume to have only one scan speed for the slow line scans. Furthermore, as flow speeds differ greatly across the microchannel for a large distance, long scan lines (e.g., above ) yield large measurement errors. Short line scans may be influenced by the nonlinear behavior of the scan mirrors at the endpoints of a scan when the mirror changes scan directions, and the measured flow angles are affected. Lines from 9 to resolve the flow directions best. The spatial resolution is important for the characterization of the flow velocity profile in a micrometer-size structure by line-scan FCS. However, the accuracy of angle determination is deteriorating as the length of scan line decreases [Fig. 4D]. As a compromise, we choose a scan line of for the optimal resolution and reasonable accuracy of flow profile measurements. 4.3.Flow Direction AnalysisFor the optimization of line-scan FCS, we investigated the influence of relative angles between microfluid flow directions and scan lines on the accuracy of analysis. However, it is demanding in practice to change the flow directions precisely in the microchannel for the current system. Alternatively, rotation of scan lines can be set through the FV300 software provided by Olympus. Slow line scans at 16 different angles between 0 and are executed when the dye solution is stationary in the microchannel or flowing. Corresponding results of laser beam line scan speeds [Fig. 5A ] and net speeds [Fig. 5B] are shown in polar graphs, where the length of scan line 1 is , line 2 is , line 3 is , and line 4 is . The standard deviation of flow directions determined by the four scan lines with different lengths in dependence of rotational angle is shown in Fig. 5C. An example of the ACF curves of the laser line scan, microfluidic flow without scanning, and microfluidic flow with line scan are shown in Fig. 5D and the goodness of the fits are confirmed by the residuals. In all measurements, the standard deviation is large when the scan line is parallel to the flow axis, while it is relatively small in the range of scanning directions perpendicular to the flow axis. 4.4.Scan Length ReductionIn the current setup without access to the control of the scan mirrors, it is possible to acquire selected parts of the fluorescence signal during forward scans, as described in Sec. 3.2. The lengths of scan lines were then effectively reduced from to , 1, and , and the respective ACF curves are shown in Fig. 6 . From the data fitting, the scan speed of the line scan was , while that of the line scan was , the line scan was , and the line scan was . The scan speed of the bidirectional line scan of was slower than that of single directional line scan of , which is due to the nonlinear scan effect at line endpoints in forward scans and also the small time fraction of backward scans for the line of . The selection of signals from the central part of the forward scan reduces the influence of nonlinear effects at the endpoints of the scan, removes the backward scan contribution, and reduces the scan line and thus increases the spatial resolution of the technique. However, the signal selection also reduces the measurement time and thus the signal collection since signals are recorded only during a fraction of the total scan. 4.5.ApplicationsTo examine the applications in different systems, slow line scans of were performed to determine the microfluidic flow directions. We investigated a microchannel with a fiber obstructed in the center [Fig. 3A, point d] and measured its flow velocity pattern. In the microchannel, flow around the fiber is constricted to the horizontal plane, which implies the formation of a 2-D flow pattern inside. Line-scan FCS measurements are performed at positions surrounding the fiber with a step size of for the determination of the flow profile. Velocity vectors were then calculated and superimposed onto an image of the microchannel [Fig. 3B], where the length of the vector represents flow speed and its arrow indicates flow direction. The resultant figure of the obstruction microfluid velocity profile is qualitatively consistent with that obtained11 by PIV. Another application of line-scan FCS is realized in small blood vessels of living zebrafish tissue. Potentially this is a label-free method since the autofluorescence of flowing proteins and red blood cells in zebrafish blood provides sufficient signal fluctuations for FCS measurements. Note that nanomolar concentrations of a fluorophore can be injected into zebrafish embryos in an early developmental stage36 when no red blood cells exist to enable FCS measurements. This still has a strong advantage over PIV, since small concentrations of fluorophores are unlikely to block small vessels. In the experiments, the blood vessel of the immobilized zebrafish on the microscopic stage was aligned to be horizontal; the schematic vectors for blood flow and line scans are superimposed onto a transmitted image [Figs. 7A, 7B ]. Single-point FCS and slow line-scan FCS were performed and all the data were fit with the two-flow model. A two-flow model must be used for adequate fitting since there are alternating slow and fast blood flows in the zebrafish cardiac cycle stemming from systolic and diastolic periods. In combination with the slow line scan, which can be treated as a single flow as shown earlier, this leads to two alternating flow patterns determined by the slow line scan overlaid with either the systolic or diastolic flow speed. The flow angle was calculated to using Eq. 5 [Fig. 7A]. A problem arises for this method in cases where there are obstructions in the scanning path, as, for instance, a blood vessel wall. For this case, a periodic signal will be seen in the ACF and the fitting of the data is difficult or even impossible, especially if the obstruction should have a slow movement itself. However, the scanning period is in the range of milliseconds or more, hence, on the time scale it will not contribute to the width of the ACF curve of the diffusion plus flow. Therefore, by recording slow line scan FCS at different rotation angles (0, 30, 45, 60, and ) the blood flow direction can still be determined [Fig. 7B]. In this example, the ACF possesses its greatest width at a scan angle of , indicating that the flow is horizontal, as expected. Scanning in multiple directions thus enables measurements of flow profiles even in small blood vessels and close to obstructions and vessel walls. In addition, this approach is independent of the focal dimensions, which can be strongly distorted in tissues. As a last point, note that the measured ACFs contain as well periodic fluctuations in the second time scale due to the heart rate of the organisms (data not shown). While this is not of interest in the flow profile measurements, it enables the accurate online monitoring of the heart beat frequency of the organism measured. Table 1Key parameters obtained by fitting ACF curves of fast, medium, and slow line scan modes with a one-flow and a two-flow model; for the ratio of τf1 over τf2 , values in parenthesis were measured by oscilloscope.
4.6.DiscussionsThe spatial resolution of line-scan FCS was limited by the length of scan lines, and was also affected by the inherent nonlinear behavior of scanning mirror mechanism at line endpoints. This problem could be solved as shown in Sec. 4.3 by using fluorescence signals collected during a specific phase of the line scan, although that reduces signal collection time and might increases the necessary measurement time. A critical drawback of the combined system lies in the fixed time ratios of forward and backward line scans, as fixed by the commercial FV300 system, which makes available a few line scan speeds. Optimized ratios, which minimize the deviation of the measurements from a one-flow model and have small nonlinearities at the scan endpoints, could be achieved by the direct control of the scanning mirrors. In that case, the spatial resolution of line-scan FCS for characterization of flow profiles might be improved further. The advantage of FCS over other methods is that only a low concentration and small-size molecules is required, and thus clogging of channels and blood vessels as can happen with PIV is not a problem. This means as well that this technique can be used in nanoscale channels too small to allow PIV measurements with microbeads. Importantly, the method works for the measurements in blood vessels when autofluorescence is high enough. Asymmetric-focus FCS requires the distortion of the focal volume interfering with the imaging capabilities of the microscope and it is ambiguous since opposite flow directions cannot be resolved and are difficult be apply to tissue measurements. Dual-beam FCS requires the installation of an extra pinhole in the instrument. In contrast to these two techniques, line-scan FCS can be implemented on any commercial or custom-built confocal microscope system based on a simple modification without interference in the imaging capabilities. In addition, by scanning the laser focus using a piezoactuator in the direction, the presented method could be extended for measurements of 3-D microfluidic flow velocities. The combination system could thus enable 3-D flow to be locally measured in the context of structural features, which is important to easily correlate the flow environments with particular cells or tissue structures in small animal bodies. This feature also has a potential application in tissue engineering to optimize the fluidic culture system. 5.ConclusionsWe performed line-scan FCS experiments on a modified laser scanning confocal microscope and demonstrated its applications in the analysis of flow profiles in microchannels and its feasibility of flow direction determination in living zebrafish blood vessels. The accuracy of line scan FCS was assessed in dependence of (1) the angle between scanning direction and flow, (2) the scan speed, and (3) the scan length used in the experiments. We chose a line scan length of as a compromise between spatial resolution and measurement accuracy. With the current setup, the measurement errors can be as low as . The potential extension of the method for 3-D microfluidic flow velocities was also discussed. Hence, line-scan FCS is a good alternative for noninvasive, minimally disturbing flow profile analyses in many applications. The combination of imaging and spectroscopy tools also facilitates a precise positioning of measurement points inside a microstructure with complicated geometry, such as fluidic microchannels, cell-culture microstructures, and biological tissues, and thus line-scan FCS could be a very useful tool for the characterization of their flow profiles. AcknowledgmentsWe acknowledge the technical assistance from other members of the Wohland and Yu laboratories and the infrastructure support from the National University Medical Institutes as well as the Institute of Bioengineering and Nanotechnology. This work is supported in part by grants from Ministry of Education, Biomedical Research Council and National Medical Research Council of Singapore. XP is a research scholar of the National University of Singapore. ReferencesB. H. Weigl,
R. L. Bardell, and
C. R. Cabrera,
“Lab-on-a-chip for drug development,”
Adv. Drug Delivery Rev., 55 349
–377
(2003). https://doi.org/10.1016/S0169-409X(02)00223-5 0169-409X Google Scholar
P. S. Dittrich and
P. Schwille,
“An integrated microfluidic system for reaction, high-sensitivity detection, and sorting of fluorescent cells and particles,”
Anal. Chem., 75 5767
–5774
(2003). https://doi.org/10.1021/ac034568c 0003-2700 Google Scholar
M. Foquet,
J. Korlach,
W. Zipfel,
W. W. Webb, and
H. G. Craighead,
“DNA fragment sizing by single molecule detection in submicrometer-sized closed fluidic channels,”
Anal. Chem., 74 1415
–1422
(2002). https://doi.org/10.1021/ac011076w 0003-2700 Google Scholar
M. U. Kopp,
A. J. Mello, and
A. Manz,
“Chemical amplification: continuous-flow PCR on a chip,”
Science, 280 1046
–1048
(1998). https://doi.org/10.1126/science.280.5366.1046 0036-8075 Google Scholar
M. J. Powers,
K. Domansky,
M. R. Kaazempur-Mofrad,
A. Kalezi,
A. Capitano,
A. Upadhyaya,
P. Kurzawski,
K. E. Wack,
D. B. Stolz,
R. Kamm, and
L. G. Griffith,
“A microfabricated array bioreactor for perfused 3D liver culture,”
Biotechnol. Bioeng., 78 257
–269
(2002). 0006-3592 Google Scholar
S. Kaihara,
J. Borenstein,
R. Koka,
S. Lalan,
E. R. Ochoa,
M. Ravens,
H. Pien,
B. Cunningham, and
J. P. Vacanti,
“Silicon micromachining to tissue engineer branched vascular channels for liver fabrication,”
Tissue Eng., 6 105
–117
(2000). https://doi.org/10.1089/107632700320739 1076-3279 Google Scholar
Y. C. Toh,
S. Ng,
Y. M. Khong,
V. Samper, and
H. Yu,
“A configurable three-dimensional microenvironment in a microfluidic channel for primary hepatocyte culture,”
Assay Drug Dev. Technol., 3 169
–176
(2005). Google Scholar
M. L. Smith,
D. S. Long,
E. R. Damiano, and
K. Ley,
“Near-wall micro-PIV reveals a hydrodynamically relevant endothelial surface layer in venules in vivo,”
Biophys. J., 85 637
–645
(2003). 0006-3495 Google Scholar
A. M. Rollins,
S. Yazdanfar,
J. K. Barton, and
J. A. Izatt,
“Real-time in vivo color Doppler optical coherence tomography,”
J. Biomed. Opt., 7 123
–129
(2002). https://doi.org/10.1117/1.1428291 1083-3668 Google Scholar
E. Nagel,
T. Thouet,
C. Klein,
S. Schalla,
A. Bornstedt,
B. Schnackenburg,
J. Hug,
E. Wellnhofer, and
E. Fleck,
“Noninvasive determination of coronary blood flow velocity with cardiovascular magnetic resonance in patients after stent deployment,”
Circulation, 107 1738
–1743
(2003). 0009-7322 Google Scholar
J. G. Santiago,
S. T. Wereley,
C. D. Meinhart,
D. J. Beebe, and
R. J. Adrian,
“A particle image velocimetry system for microfluidics,”
Exp. Fluids, 25 316
–319
(1998). https://doi.org/10.1007/s003480050235 0723-4864 Google Scholar
H. Cheng,
Q. Luo,
S. Zeng,
S. Chen,
J. Cen, and
H. Gong,
“Modified laser speckle imaging method with improved spatial resolution,”
J. Biomed. Opt., 8 559
–564
(2003). https://doi.org/10.1117/1.1578089 1083-3668 Google Scholar
W. Wang,
Y. Liu,
G. J. Sonek,
M. W. Berns, and
R. A. Keller,
“Optical trapping and fluorescence detection in laminar flow streams,”
Appl. Phys. Lett., 67 1057
–1059
(1995). https://doi.org/10.1063/1.114463 0003-6951 Google Scholar
B. Manz,
P. Stilbs,
B. Joensson,
O. Soederman, and
P. T. Callaghan,
“NMR imaging of the time evolution of electroosmotic flow in a capillary,”
J. Phys. Chem., 99 11297
–11301
(1995). https://doi.org/10.1021/j100029a001 0022-3654 Google Scholar
E. L. Elson and
D. Magde,
“Fluorescence correlation spectroscopy. I. Conceptual basis and theory,”
Biopolymers, 13 1
–27
(1974). https://doi.org/10.1002/bip.1974.360130102 0006-3525 Google Scholar
D. Magde,
W. W. Webb, and
E. L. Elson,
“Fluorescence correlation spectroscopy. III. uniform translation and laminar flow,”
Biopolymers, 17 361
–376
(1978). https://doi.org/10.1002/bip.1978.360170208 0006-3525 Google Scholar
R. H. Kohler,
P. Schwille,
W. W. Webb, and
M. R. Hanson,
“Active protein transport through plastid tubules: velocity quantified by fluorescence correlation spectroscopy,”
J. Cell. Sci., 113 3921
–3930
(2000). 0021-9533 Google Scholar
B. H. Kunst,
A. Schots, and
A. J. Visser,
“Detection of flowing fluorescent particles in a microcapillary using fluorescence correlation spectroscopy,”
Anal. Chem., 74 5350
–5357
(2002). https://doi.org/10.1021/ac0256742 0003-2700 Google Scholar
M. Gosch,
H. Blom,
J. Holm,
T. Heino, and
R. Rigler,
“Hydrodynamic flow profiling in microchannel structures by single molecule fluorescence correlation spectroscopy,”
Anal. Chem., 72 3260
–3265
(2000). https://doi.org/10.1021/ac991448p 0003-2700 Google Scholar
K. K. Kuricheti,
V. Buschmann, and
K. D. Weston,
“Application of fluorescence correlation spectroscopy for velocity imaging in microfluidic devices,”
Appl. Spectrosc., 58 1180
–1186
(2004). 0003-7028 Google Scholar
P. F. Lenne,
D. Colombo,
H. Giovannini, and
H. Rigneault,
“Flow profiles and directionality in microcapillaries measured by fluorescence correlation spectroscopy,”
Single Mol., 3 194
–200
(2002). https://doi.org/10.1002/1438-5171(200208)3:4<194::AID-SIMO194>3.0.CO;2-0 1438-5163 Google Scholar
M. Brinkmeier,
K. Dorre,
J. Stephan, and
M. Eigen,
“Two-beam cross-correlation: a method to characterize transport phenomena in micrometer-sized structures,”
Anal. Chem., 71 609
–616
(1999). https://doi.org/10.1021/ac980820i 0003-2700 Google Scholar
K. Q. Xia and
Y. B. Xin,
“Dual-beam incoherent cross-correlation spectroscopy,”
J. Opt. Soc. Am. A, 12 1571
–1578
(1995). 0740-3232 Google Scholar
P. S. Dittrich and
P. Schwille,
“Spatial two-photon fluorescence cross-correlation spectroscopy for controlling molecular transport in microfluidic structures,”
Anal. Chem., 74 4472
–4479
(2002). https://doi.org/10.1021/ac025625p 0003-2700 Google Scholar
N. O. Petersen,
“Scanning fluorescence correlation spectroscopy. I. Theory and simulation of aggregation measurements,”
Biophys. J., 49 809
–815
(1986). 0006-3495 Google Scholar
D. E. Koppel,
F. Morgan,
A. E. Cowan, and
J. H. Carson,
“Scanning concentration correlation spectroscopy using the confocal laser microscope,”
Biophys. J., 66 502
–507
(1994). 0006-3495 Google Scholar
K. M. Berland,
P. T. So,
Y. Chen,
W. W. Mantulin, and
E. Gratton,
“Scanning two-photon fluctuation correlation spectroscopy: particle counting measurements for detection of molecular aggregation,”
Biophys. J., 71 410
–420
(1996). 0006-3495 Google Scholar
B. Hebert,
S. Costantino, and
P. W. Wiseman,
“Spatiotemporal image correlation spectroscopy (STICS) theory, verification, and application to protein velocity mapping in living CHO cells,”
Biophys. J., 88 3601
–3614
(2005). 0006-3495 Google Scholar
J. P. Skinner,
Y. Chen, and
J. D. Muller,
“Position-sensitive scanning fluorescence correlation spectroscopy,”
Biophys. J., 89 1288
–1301
(2005). https://doi.org/10.1529/biophysj.105.060749 0006-3495 Google Scholar
R. Rigler,
U. Mets,
J. Widengren, and
P. Kask,
“Fluorescence correlation spectroscopy with high count rate and low background: analysis of translational diffusion,”
Eur. Biophys. J., 22 169
–175
(1993). https://doi.org/10.1007/BF00185777 0175-7571 Google Scholar
J. Widengren,
U. Mets, and
R. Rigler,
“Fluorescence correlation spectroscopy of triplet states in solution: a theoretical and experimental study,”
J. Phys. Chem., 99 13368
–13379
(1995). https://doi.org/10.1021/j100036a009 0022-3654 Google Scholar
M. Westerfield, The Zebrafish Book. A Guide for the Laboratory Use of Zebrafish (Danio rerio), 4th ed.Univ. of Oregon Press, Eugene (2000). Google Scholar
D. E. Koppel,
“Statistical accuracy in fluorescence correlation spectroscopy,”
Phys. Rev. A, 10 1938
–1945
(1974). https://doi.org/10.1103/PhysRevA.10.1938 1050-2947 Google Scholar
T. Wohland,
R. Rigler, and
H. Vogel,
“The standard deviation in fluorescence correlation spectroscopy,”
Biophys. J., 80 2987
–2999
(2001). 0006-3495 Google Scholar
U. Meseth,
T. Wohland,
R. Rigler, and
H. Vogel,
“Resolution of fluorescence correlation measurements,”
Biophys. J., 76 1619
–1631
(1999). 0006-3495 Google Scholar
S. Isogai,
M. Horiguchi, and
B. M. Weinstein,
“The vascular anatomy of the developing zebrafish: an atlas of embryonic and early larval development,”
Dev. Biol., 230 278
–301
(2001). 0012-1606 Google Scholar
|